Skip to Content
MilliporeSigma
  • Determination of polychlorinated biphenyls by liquid chromatography-atmospheric pressure photoionization-mass spectrometry.

Determination of polychlorinated biphenyls by liquid chromatography-atmospheric pressure photoionization-mass spectrometry.

Journal of mass spectrometry : JMS (2014-11-15)
Athanasios I Moukas, Nikolaos S Thomaidis, Antonios C Calokerinos
ABSTRACT

This study presents the atmospheric pressure photoionization (APPI) of high-chlorinated (five or more chlorine atoms) polychlorinated biphenyls (PCBs) using toluene as dopant, after liquid chromatographic separation. Mass spectra of PCB 101, 118, 138, 153, 180, 199, 206 and 209 were recorded by using liquid chromatography-APPI-tandem mass spectrometry (LC-APPI-MS/MS) in negative ion full scan mode. Intense peaks appeared at m/z that correspond to [M - Cl + O](-) ions, where M is the analyte molecule. Furthermore, a detailed strategy, which includes designs of experiments, for the development and optimization of LC-APPI-MS/MS methods is described. Following this strategy, a sensitive and accurate method with low instrumental limits of detection, ranging from 0.29 pg for PCB 209 to 8.3 pg for PCB 101 on column, was developed. For the separation of the analytes, a Waters XSELECT HSS T3 (100 mm × 2.1 mm, 2.5 µm) column was used with methanol/water as elution system. This method was applied for the determination of the above PCBs in water samples (surface water, tap water and treated wastewater). For the extraction of PCBs from water samples, a simple liquid-liquid extraction with dichloromethane was used. Method limits of quantification, ranged from 4.8 ng l(-1), for PCB 199, to 9.4 ng l(-1), for PCB 180, and the recoveries ranged from 73%, for PCB 101, to 96%, for PCB 199. The estimated analytical figures were appropriate for trace analysis of high-chlorinated PCBs in real samples.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile, for residue analysis, JIS 5000
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Supelco
Dichloromethane solution, contains 10 % (v/v) methanol
Sigma-Aldrich
Dichloromethane, SAJ first grade, ≥99.0%
Sigma-Aldrich
Toluene, SAJ first grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
2,2,4-Trimethylpentane, SAJ first grade, ≥98.0%
Sigma-Aldrich
Toluene, JIS 1000, for residue analysis, ≥99.8%
Sigma-Aldrich
Acetonitrile, ≥99.8%, for residue analysis, JIS 1000
Sigma-Aldrich
Toluene, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, ≥99.8%, for residue analysis, JIS 300
Sigma-Aldrich
Toluene, JIS 300, for residue analysis, ≥99.8%
Sigma-Aldrich
Dichloromethane, JIS special grade, ≥99.0%
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Sigma-Aldrich
Anisole, anhydrous, 99.7%
Supelco
Acetonitrile, HPLC grade, ≥99.93%
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
2,2,4-Trimethylpentane, JIS special grade
Sigma-Aldrich
Acetonitrile, for chromatography
Supelco
Dichloromethane, Selectophore, ≥99.5%
Supelco
Anisole, analytical standard
Supelco
Acetonitrile, analytical standard
Supelco
Toluene, analytical standard
Supelco
Toluene, HPLC grade, 99.8%
Supelco
Dichloromethane, ≥99.9%
Sigma-Aldrich
2,2,4-Trimethylpentane, anhydrous, 99.8%
Sigma-Aldrich
Toluene, anhydrous, 99.8%
Sigma-Aldrich
Dichloromethane, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Acetonitrile, ≥99.5%, ACS reagent