T-076
L-Thyroxine-13C6 solution
100 μg/mL in methanol with 0.1N NH3, ampule of 1 mL, certified reference material, Cerilliant®
About This Item
Recommended Products
grade
certified reference material
form
liquid
feature
(Snap-N-Spike®)
packaging
ampule of 1 mL
manufacturer/tradename
Cerilliant®
concentration
100 μg/mL in methanol with 0.1N NH3
technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
application(s)
clinical testing
format
single component solution
storage temp.
−20°C
SMILES string
I[13C]1=[13C]([13C](I)=[13CH][13C](C[C@@H](C(O)=O)N)=[13CH]1)OC2=CC(I)=C(O)C(I)=C2
InChI
1S/C15H11I4NO4/c16-8-4-7(5-9(17)13(8)21)24-14-10(18)1-6(2-11(14)19)3-12(20)15(22)23/h1-2,4-5,12,21H,3,20H2,(H,22,23)/t12-/m0/s1/i1+1,2+1,6+1,10+1,11+1,14+1
InChI key
XUIIKFGFIJCVMT-PDHVKVOFSA-N
General description
L-Thyroxine-13C6 is an isotopically labeled form of the tyrosine-based thyroid hormone, thyroxine (T4). Thyroxine is secreted by the thyroid gland and is involved in different biological processes, such as growth, neurodevelopment, carbohydrate & oxygen metabolism, and protein synthesis
application
- Combination of hollow fiber-liquid-phase microextraction (HF-LPME) based sample preparation and liquid chromatography-tandem mass spectrometric (LC-MS/MS) determination of total thyroxine in serum samples
- Development of an LC-MS/MS method for the multi-residue analysis of melatonin, cortisol, triiodothyronine, thyroxine, and testosterone in rat serum samples following their dual liquid-liquid extraction
- Simultaneous determination of thyroxine by an isotope dilution-matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) method from human serum samples
- Estimation of thyroxine (T4) and triiodothyronine (T3) in rat cardiac tissue samples by a high-performance liquid chromatographic-tandem mass spectrometric (HPLC-MS/MS) method following their derivatization
- Establishing and validating an LC-MS/MS-based method for the quantification of endogenous thyroid hormones, T4 and two of its T3 isomers, in tissue samples obtained from lamprey, following the enzymatic digestion and protein precipitation of the samples
Features and Benefits
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
Legal Information
related product
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
target_organs
Eyes,Central nervous system
Storage Class
3 - Flammable liquids
wgk_germany
WGK 2
flash_point_f
49.5 °F
flash_point_c
9.7 °C
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service