About This Item
Polecane produkty
pochodzenie biologiczne
human esophagus
tryb wzrostu
Suspension
kariotyp
Not specified
morfologia
Large spherical clumps of cells loosely adherent to the plastic
produkty
P53 mutation c.742C>T
receptory
Not specified
metody
cell culture | mammalian: suitable
powiązane choroby
metastasis
Warunki transportu
dry ice
temp. przechowywania
−196°C
Powiązane kategorie
Pochodzenie linii komórkowej
Adenocarcinoma of the gastroesophageal junction
Opis linii komórkowej
ESO26 was established from a primary tumour located in the gastroesophageal junction and distal oesophagus of a 56 year-old Caucasian male in 2000 involving lymph nodes and distant metastases. ESO26 was found to be tumourigenic in female NMRI nude mice or NOD-SCID mice.
Profil DNA
STR-PCR Data:
Amelogenin: X,Y
CSF1PO: 9,10
D13S317: 9,11
D16S539: 9
D5S818: 12
D7S820: 11
THO1: 9
TPOX: 7,9
vWA: 14,18
Amelogenin: X,Y
CSF1PO: 9,10
D13S317: 9,11
D16S539: 9
D5S818: 12
D7S820: 11
THO1: 9
TPOX: 7,9
vWA: 14,18
pożywka hodowlana
RPMI-1640 + 2 mM Glutamine + 10% Foetal Bovine Serum (FBS)
Rutyna subkultury
Maintain cultures between 2-9 x 105 cells/cm3. Cells are loosely adherent and can be dislodged by gentle tapping or use of 0.02% EDTA solution. 5% CO2; 37 °C.
Inne uwagi
Additional freight & handling charges may be applicable for Asia-Pacific shipments. Please check with your local Customer Service representative for more information.
Cultures from HPA Culture Collections and supplied by Sigma are for research purposes only. Enquiries regarding the commercial use of a cell line are referred to the depositor of the cell line. Some cell lines have additional special release conditions such as the requirement for a material transfer agreement to be completed by the potential recipient prior to the supply of the cell line. Please view the Terms & Conditions of Supply for more information.
Oświadczenie o zrzeczeniu się odpowiedzialności
RESEARCH USE ONLY. This product is regulated in France when intended to be used for scientific purposes, including for import and export activities (Article L 1211-1 paragraph 2 of the Public Health Code). The purchaser (i.e. enduser) is required to obtain an import authorization from the France Ministry of Research referred in the Article L1245-5-1 II. of Public Health Code. By ordering this product, you are confirming that you have obtained the proper import authorization.
Kod klasy składowania
10 - Combustible liquids
Klasa zagrożenia wodnego (WGK)
WGK 3
Temperatura zapłonu (°F)
Not applicable
Temperatura zapłonu (°C)
Not applicable
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej