UFC9010D
Amicon® Ultra-15 Centrifugal Filter Unit, registered for IVD use
Synonim(y):
Centrifugal ultrafiltration device, 10 kDa MWCO, 15 mL sample volume
About This Item
Polecane produkty
Materiały
polyethylene cap
polypropylene tube
regenerated cellulose membrane
styrene-butadiene housing
Poziom jakości
sterylność
non-sterile
linia produktu
Amicon®
opakowanie
pack of 24 ea (UFC901024D)
pack of 8 ea (UFC901008D)
pack of 96 ea (UFC901096D)
producent / nazwa handlowa
Amicon® Ultra
metody
centrifugation: suitable (protein concentration and desalting)
protein extraction: suitable
protein purification: suitable
Długość
121 mm (4.807 in.)
Średnica
2.97 cm
powierzchnia filtracyjna
7.6 cm2
pojemność
15 mL
wielkość porów
10 kDa MWCO
Opis ogólny
The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold concentration. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss.
The concentrate is collected from the filter device sample reservoir using a pipetter, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging bucket or fixed angle rotor. With their vertical membrane design and deadstop, Amicon® Ultra 15 mL filters deliver the highest recovery with short spin times.
Zastosowanie
- Ultrafiltration with 10,000 dalton molecular weight cutoff Ultracel® membrane.
- Concentration of serum, urine, cerebrospinal fluid and other body fluids prior to analysis.
- Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLS.
- Concentration of dilute or pre-purified proteins from column eluents.
- Desalting, buffer exchange and protein dialysis.
Cechy i korzyści
- In vitro diagnostic medical device with CE conformity marking.
- Ultracel® regenerated cellulose membrane with 10 kDa NMWCO delivers retentate recovery of greater than 90%.
- Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10–15 minutes).
- Heat-sealed membrane minimizes downstream extractables.
- 100% integrity tested for reliable performance.
- Convenient sample monitoring with translucent housing and volume gradations.
- Direct pipettor sample access eliminates processing step to recover concentrate.
- High concentration factors of 80–100X.
Informacje prawne
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Klienci oglądali również te produkty
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.