Wybierz wielkość
| Rozmiar/SKU | Dostępność | Cena netto |
|---|---|---|
10 ea | Przewidywany termin wysyłki07 września 2026zKuehne + Nagel Sp. z o.o. | 2540,00 zł |
Informacje o tej pozycji
Quality Segment
material
Nylon 66 adapter (for needle), PVC tubing (double lumen), mixed cellulose esters (MCE) membrane, plain filter, stainless steel (for needle), styrene-acrylonitrile (SAN) (for canister)
agency
EP (2.6.1), JP (4.06), USP 71
sterility
sterile; γ-irradiated
feature
Blue base canister with a vented double needle for large glass containers with septa.
manufacturer/tradename
Steritest®
packaging
pkg of 10 blisters in 2 bags of 5 blisters per box, Double packed
parameter
120 mL sample volume (graduation marks at 25, 50, 75 and 100 mL), 3.1 bar max. inlet pressure (45 psi) at 25 °C, 45 °C max. temp.
tubing L
850 mm
color
blue Canister Base
matrix
MF-Millipore™
pore size
0.45 μm pore size
input
liquid
sample type pharmaceutical(s)
application(s)
pharmaceutical
sterility testing
compatibility
For liquids in large vials.
shipped in
ambient
General description
Steritest® NEO Device is a membrane filtration device for sterility testing of filterable pharmaceutical products. The device simplifies every aspect of testing, from handling to traceability. The closed system minimizes false positives and offers the highest levels of quality and reliability. This device ensures that pharmaceutical products are never exposed to the environment during the testing process. This test system offers an optimized and fully regulatory compliant testing process, when used with the Steritest® Symbio pump, specific accessories and high-quality culture media and rinsing fluids. The device is gamma sterilized and double packed for the quick transfer into sterility testing environments, simplifying decontamination procedures and saving time. A vented needle adapter vents and transfers the test product from large volume containers with a septum to the Steritest® NEO devices. The blue based canisters indicate mixed cellulose esters (MCE) membrane, which provides an optimal filtration flow rate for standard products.
Application
Features and Benefits
- One-stop-shop for sterility testing with our devices, pumps, media, fluids, and services
- Steritest® devices are manufactured in our Center of Excellence in Molsheim, France, with high-quality control standards maintaining the Certificate of Quality for each lot.
- New needle design
- Smarter workflow
- Completely closed set up
- Consistent performance
- New tubing disconnection tool
Packaging
Legal Information
1 of 1
Ta pozycja | |||
|---|---|---|---|
| description For liquids in large vials., Blue base canister with a vented double needle for large glass containers with septa., pkg of 10 blisters in 2 bags of 5 blisters per box, Double packed | description For soluble powders in ampoules., Blue base canister with a single needle for transfer into and out of ampoules. | description For medical devices and collapsible bags., Blue base canister provided with 3 adaptors for connecting various test devices. | description For liquids in small vials with septa., Red base canister with a vented double needle for small vials with septa., pkg of 10 blisters per box, Single packed |
| compatibility For liquids in large vials. | compatibility For soluble powders in ampoules. | compatibility for use with Steritest® Symbio ISL Pump Kit, 2 media (SYMBISL01), for use with Steritest® Symbio FLEX Pump Kit, 2 media (SYMBFLE01), For medical devices and collapsible bags., for use with Steritest® Symbio LFH Pump Kit (SYMBLFH01) | compatibility For liquids in small vials with septa., for use with Steritest® Symbio LFH Pump Kit (SYMBLFH01), for use with Steritest® Symbio ISL Pump Kit, 2 media (SYMBISL01), for use with Steritest® Symbio FLEX Pump Kit, 2 media (SYMBFLE01) |
| material mixed cellulose esters (MCE) membrane, stainless steel (for needle), PVC tubing (double lumen), plain filter, Nylon 66 adapter (for needle), styrene-acrylonitrile (SAN) (for canister) | material Nylon 66 adapter (for needle), mixed cellulose esters (MCE) membrane, PVC tubing (double lumen), styrene-acrylonitrile (SAN) (for canister), stainless steel (for needle), plain filter | material PVC tubing (double lumen), Nylon 66 adapter (for needle), stainless steel ( for needle), plain filter, styrene-acrylonitrile (SAN) ( for Canister), mixed cellulose esters (MCE) membrane | material Nylon 66 adapter (for needle), PVC tubing (double lumen), PVDF membrane, stainless steel (for needle), styrene-acrylonitrile (SAN) (for Canister), plain filter |
| shipped in ambient | shipped in ambient | shipped in ambient | shipped in ambient |
| packaging pkg of 10 blisters in 2 bags of 5 blisters per box, Double packed | packaging pkg of 10 blisters per box, Single packed | packaging pkg of 10 blisters per box, Single packed | packaging pkg of 10 blisters per box, Single packed |
| parameter 45 °C max. temp., 120 mL sample volume (graduation marks at 25, 50, 75 and 100 mL), 3.1 bar max. inlet pressure (45 psi) at 25 °C | parameter 3.1 bar max. inlet pressure (45 psi) at 25 °C, 45 °C max. temp., 120 mL sample volume (graduation marks at 25, 50, 75 and 100 mL) | parameter 3.1 bar max. inlet pressure (45 psi) at 25 °C, 120 mL sample volume (graduation marks at 25, 50, 75 and 100 mL), 45 °C max. temp. | parameter 120 mL sample volume (graduation marks at 25, 50, 75 and 100 mL), 3.1 bar max. inlet pressure (45 psi) at 25 °C, 45 °C max. temp. |
| manufacturer/tradename Steritest® | manufacturer/tradename Steritest® | manufacturer/tradename Steritest® | manufacturer/tradename Steritest® |
Still not finding the right product?
Explore all of our products under Steritest® NEO Device
Klasa składowania
11 - Combustible Solids
wgk
WGK 2
Wybierz jedną z najnowszych wersji:
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.