Pellicon® 3 Cassette with Ultracel® Membrane

filtration area 88 cm2, NMWCO 10 kDa

Synonim(y):

Pellicon® 3 Cassette with Ultracel® 10 kDa Membrane, C Screen, 88 cm2

Zaloguj się, aby wyświetlić ceny organizacyjne i kontraktowe.

Wybierz wielkość

Zmień widok
Rozmiar/SKUDostępnośćCena netto
1 ea

Przewidywany termin wysyłki26 stycznia 2027zKuehne + Nagel Sp. z o.o.

2910,00 zł

Informacje o tej pozycji

UNSPSC Code:
41104903
NACRES:
NB.24
eCl@ss:
32031602

2910,00 zł


Przewidywany termin wysyłki26 stycznia 2027Szczegóły


​
Pomoc techniczna
Potrzebujesz pomocy? Nasz zespół doświadczonych naukowców chętnie Ci pomoże.
Pozwól nam pomóc


Quality Segment

material

TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene cap (for end), polypropylene screen

product line

Pellicon®

feature

holdup volume 1.5 mL (in feed channel)

manufacturer/tradename

Pellicon®

parameter

2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration), tangential flow filtration (TFF): suitable

H

0.8 cm (0.33 in.)

L

20.6 cm (8.1 in.)

W

5.6 cm (2.2 in.)

filtration area

88 cm2

membrane area

88 cm2

gravimetric extractables

≤1500 mg/m2

matrix

Ultracel® (Membrane)

pore size

10 kDa NMWCO

pH

2-13

shipped in

ambient

General description

Pellicon® 3 filtration devices are advanced, high-performance cassettes ideal for today’s higher titer therapeutic antibodies as well as the more demanding filtration processes that require higher operating pressures, temperatures and caustic cleaning regimes.

The Pellicon® 3 Cassette with Ultracel® Membrane is designed for the filtration of therapeutic proteins (such as monoclonal antibodies) and recombinant and non-recombinant proteins.

This P3C010C00 Pellicon® 3 ultrafiltration device features a pore size of 10 kDa NMWCO, a filtration area of 88 cm2, a PLCGC membrane, and dimensions measuring 2.4 cm (H) x 17.8 cm (W) x 20.6 cm (L).

Features and Benefits

  • Rugged & reliable – ideally suited for today′s more demanding filtration processes
  • High performance – produces excellent resolution, yields and back-pressure resistance
  • Optimum product recovery – thanks to proven membrane technology
  • Void-free technology – leading-edge membranes resolve virtually any separation challenge
  • Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
  • Automated manufacturing – delivers unbeatable performance, consistency and reliability
  • Easy installation & care – simple to install and maintain

Analysis Note

Gravimetric Extractables: after 24 hours in water at controlled room temperature

Other Notes

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.

Porównaj podobne pozycje

Wyświetl pełne porównanie

Pokaż różnice

1 of 1

Ta pozycja
P3C030C10P3C030C00P3C010C01
description

filtration area 88 cm2, NMWCO 10 kDa

description

filtration area 1.14 m2, NMWCO 30 kDa, Holdup volume 170 mL

description

filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 1.5 mL (in feed channel)

description

filtration area 0.11 m2, NMWCO 10 kDa

pore size

10 kDa NMWCO

pore size

30 kDa NMWCO

pore size

30 kDa NMWCO

pore size

10 kDa NMWCO

technique(s)

tangential flow filtration (TFF): suitable, protein purification: suitable (concentration), analytical sample preparation: suitable, buffer exchange: suitable

technique(s)

protein purification: suitable (concentration), buffer exchange: suitable, tangential flow filtration (TFF): suitable, analytical sample preparation: suitable

technique(s)

buffer exchange: suitable, analytical sample preparation: suitable, protein purification: suitable (concentration), tangential flow filtration (TFF): suitable

technique(s)

buffer exchange: suitable, tangential flow filtration (TFF): suitable, analytical sample preparation: suitable, protein purification: suitable (concentration)

filtration area

88 cm2

filtration area

1.14 m2

filtration area

88 cm2

filtration area

0.11 m2

product line

Pellicon®

product line

Pellicon®

product line

Pellicon®

product line

Pellicon®

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

material

TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene screen, polypropylene cap (for end)

material

stainless steel cap (for end; polypropylene-encapsulated), polypropylene screen, composite regenerated cellulose (CRC) , TPE seal

material

polypropylene , TPE seal, polypropylene screen, polypropylene cap (for end), composite regenerated cellulose (CRC) membrane

material

composite regenerated cellulose (CRC) , polypropylene cap (for end), TPE seal, polypropylene screen


Still not finding the right product?


Klasa składowania

10 - Combustible liquids

WGK

WGK 2


Wykazy regulacyjne

Wykazy regulacyjne dotyczą głównie produktów chemicznych. Można w nich podawać ograniczoną liczbę informacji na temat produktów niechemicznych. Brak wpisu oznacza, że żaden ze składników nie znajduje się w wykazie. Użytkownik odpowiada za zagwarantowanie bezpiecznego i zgodnego z prawem stosowania produktu.

64-19-7

CAS No.


Zgodność z GMP dzięki programowi Emprove®

Przyspiesz kwalifikacje, zachowaj zgodność i oszczędzaj czas dzięki Emprove® Dossiers.

Pobierz Dossiers

Uwaga: zostaniesz przeniesiony do EmproveSuite.com. Twoja nazwa użytkownika i hasło są niezależne od SigmaAldrich.com i mogą się różnić.

Zarejestruj się za darmo i uzyskaj dostęp do Emprove® Dossiers w ciągu kilku minut. Uaktualnij swój plan subskrypcji, aby odblokować zaawansowaną i spersonalizowaną zawartość w Emprove® Suite.

Nie znalazłeś tego, czego szukasz? Odwiedź stronę pomocy programu Emprove®..

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Masz trudności ze znalezieniem produktu lub numeru serii/partii?

Podczas wyświetlania na stronie internetowej numery produktów są łączone z wielkością przesyłki / ilością (przykład: T1503-25G). Pamiętaj że w polu „Numer produktu” należy podać TYLKO numer produktu (przykład: T1503).

Przykład:

T1503
Numer produktu
-
25G
Wielkość opakowania/ilość

Przykłady dodatkowe:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

wpisz jako 1.000309185)

Mieć kłopoty? Poczuj się swobodnie w kontakcie Pomoc techniczna dla wsparcia



Questions

Reviews

No rating value

Active Filters