Przejdź do zawartości
Merck

Przejdź do

MPGL04GK2

Millipak® 40 Gamma Gold Capsule Media: Sterile Durapore® 0.22 µm

Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF) Inlet: 1/4 in. NPTM Outlet: 1/4 in. Stepped Hose Barb with Bell

Synonim(y):

Millipak® 40 Gamma Gold Filter, Millipak® Gold Filter

, aby wyświetlić ceny organizacyjne i kontraktowe.

Wybierz wielkość

Zmień widok
Do Państwa/SKUDostępnośćCena netto
2 ea

Przewidywany termin wysyłki07 lipca 2026zKuehne + Nagel Sp. z o.o.

1400,00 zł

Informacje o tej pozycji

UNSPSC Code:
41104212
NACRES:
JA.14
eCl@ss:
33050190

1400,00 zł


Przewidywany termin wysyłki07 lipca 2026Szczegóły


Więcej informacji
Pomoc techniczna
Potrzebujesz pomocy? Nasz zespół doświadczonych naukowców chętnie Ci pomoże.
Pozwól nam pomóc


Nazwa produktu

Millipak® 40 Gamma Gold Capsule Media: Sterile Durapore® 0.22 µm, Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF) Inlet: 1/4 in. NPTM Outlet: 1/4 in. Stepped Hose Barb with Bell

material

PVDF membrane

Quality Segment

description

Sterile 0.22 μm membrane filter to remove particulates and bacteria at the point of dispense. For Milli-Q® Advantage A10/Academic/Biocel/Element/Synthesis/Plus/Gradient, Alpha-Q and Milli-DI® systems.

sterility

sterile

product line

EMPROVE® Filter

feature

hydrophilic

packaging

pkg of 2 units

manufacturer/tradename

Millipak®

parameter

0.35 bar max. differential pressure at 123 °C (Forward), 0.7 bar max. differential pressure at 25 °C (Reverse), 1.7 bar max. differential pressure at 80 °C (Forward), 4.1 bar max. differential pressure at 25 °C (Forward), 5.2 bar max. inlet pressure at 25 °C

inlet connection diam.

1/4 in.

outlet connection diam.

1/4 in.

impurities

<0.5  EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

gravimetric extractables

≤1.5 mg/device

matrix

Durapore®

pore size

0.22 μm pore size

fitting

male NPT inlet connection, outlet stepped hose barb (with bell)

compatibility

for use with Alpha-Q, for use with Milli-DI®, for use with Milli-Q® Academic, for use with Milli-Q® Advantage A10, for use with Milli-Q® Biocel, for use with Milli-Q® Direct, for use with Milli-Q® Element, for use with Milli-Q® Gradient, for use with Milli-Q® Plus, for use with Milli-Q® Reference, for use with Milli-Q® Synthesis

shipped in

ambient

General description

Millipak® membrane products are designed for routine filtration applications in the laboratory. Millipak® filters are best-in-class, proven products, used in lab water purification systems to remove particulates and bacteria to benefit the stringent requirements of scientific applications.

Application

Removes bacteria and particulates in ultrapure water, making it suitable for techniques used in the laboratory where bacterial control is crucial (cell culture, microbiology media preparation, etc.).

Features and Benefits

  • Millipak® membrane filters are made with Durapore® PVDF membranes to provide high flow rates and throughputs, low extractable and broad chemical compatibility.
  • Gamma-irradiated for additional bacteria control.
  • The membrane is supported by a rigid plastic disc with channels that ensures high water flow and resistance to pressure variations without the risk of membrane rupture.
  • Millipak® membrane filters use the unique, clean stacked disc design, allowing minimal hold-up volume and particle shedding.
  • Connects to the outlet of the water delivery point, such as the PODs of Milli-Q® water purification systems.The protective bell protects against intrusion of airborne bacteria contamination during dispensing.
  • The protective bell protects against intrusion of airborne bacteria contamination during dispensing.
  • Care-free maintenance: the filter is easily fitted and replaced.
  • Device configuration: Gamma Gold Capsule.
  • Sterile unit.
  • Delivered hermetically sealed, with its Certificate of Quality.

Preparation Note

This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: using sterilized device after a 200 mL flush and 24 hours in water at controlled room temperature

Other Notes

Directions for Use

  • Organism Retention: Microorganisms
  • Mode of Action: Filtering
  • Application: General laboratory analysis
  • Intended Use: Water purification
  • Instructions for Use: This item provides water filtered through 0.22 μm sterilizing-grade membranes. Refer to system equipment user guide section "Using the System" (available on USB key in the system box).
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
Emprove is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLI-DI is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPAK is a registered trademark of Merck KGaA, Darmstadt, Germany
Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.

Porównaj podobne pozycje

Wyświetl pełne porównanie

Pokaż różnice

1 of 1

Ta pozycja
MPGL10ZW1MPGP002A1MPGP02001
compatibility

for use with Alpha-Q, for use with Milli-Q® Academic, for use with Milli-Q® Biocel, for use with Milli-Q® Element, for use with Milli-Q® Plus, for use with Milli-Q® Synthesis, for use with Milli-DI®, for use with Milli-Q® Direct, for use with Milli-Q® Reference, for use with Milli-Q® Advantage A10, for use with Milli-Q® Gradient

compatibility

for use with AFS®

compatibility

for use with Milli-Q® EQ 7000, for use with Milli-Q® EQ 7008, for use with Milli-Q® EQ 7016, for use with Milli-Q® IX 7003, for use with Milli-Q® IX 7005, for use with Milli-Q® IX 7010, for use with Milli-Q® IX 7015, for use with Milli-Q® IQ 7000, for use with Milli-Q® IQ 7003, for use with Milli-Q® IQ 7005, for use with Milli-Q® IQ 7010, for use with Milli-Q® IQ 7015

compatibility

for use with Direct-Q® UV, for use with Milli-Q® Academic, for use with Milli-Q® Biocel, for use with Milli-Q® Element, for use with Milli-Q® Gradient, for use with Milli-Q® Synthesis, for use with Synergy® UV

pore size

0.22 μm pore size

pore size

0.22 μm pore size

pore size

0.22 μm pore size

pore size

0.22 μm pore size

sterility

sterile

sterility

non-sterile

sterility

-

sterility

non-sterile

manufacturer/tradename

Millipak®

manufacturer/tradename

Millipak®

manufacturer/tradename

Millipak®

manufacturer/tradename

Millipak®

packaging

pkg of 2 units

packaging

pkg of 1 unit

packaging

pkg of 1 unit

packaging

pkg of 1 unit

impurities

<0.5  EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

impurities

<0.5  EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

impurities

-

impurities

-


Still not finding the right product?




Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów



Questions

  1. Is there an alternative to MPGL04GK2? We change filters every 3 months.

    1 answer
    1. •The replacement part for a MPGL04GK2 is item number MPGL04001, which is the non-sterilized version of this filter.
      • Apart from this, there does not seem to be a direct replacement.
      • Note that MPGL04001 is autoclavable and can withstand up to 3 cycles of autoclaving for 90 minutes at 123°C.

      Helpful?

Reviews

No rating value

Active Filters