Nazwa produktu
Opticap® XL 10 CapsuleMedia: Durapore® 0.45 µm, Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF)Inlet: 3/4 in. Sanitary FlangeOutlet: 3/4 in. Sanitary FlangeMax Operating Pressure: 80 psi @ 25 °C
Quality Segment
material
PVDF , polypropylene , polypropylene housing, polypropylene support, polypropylene vent cap, silicone seal
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
autoclavable compatible
product line
Opticap® XL 10
feature
hydrophilic
manufacturer/tradename
Opticap®
parameter
≤15 mL/min air diffusion at 1.5 bar (22 psig) and 23 °C (in water), 1.0 bar max. inlet pressure (15 psi) at 80 °C, 2.8 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 3.4 bar max. differential pressure (50 psid) at 25 °C (Forward), 3.4 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent), 5.5 bar max. inlet pressure (80 psi) at 23 °C, 80 psig max. inlet pressure
technique(s)
bioburden reduction: suitable
L
13.2 in.
W
4.2 in.
cartridge nominal length
10 in. (25 cm)
diam.
10.7 cm (4.2 in.)
filtration area
0.69 m2
inlet connection diam.
3/4 in.
inlet to outlet W
33.0 cm (13.0 in.)
outlet connection diam.
3/4 in.
impurities
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction), <0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
gravimetric extractables
≤25 mg/capsule
matrix
Durapore®
pore size
0.45 μm
input
sample type liquid
bubble point
≥1930 mbar (28 psig), air with water at 23 °C
fitting
General description
Packaging
Preparation Note
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Analysis Note
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Legal Information
Disclaimer
1 of 1
Ta pozycja | |||
|---|---|---|---|
| description Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF)Inlet: 3/4 in. Sanitary FlangeOutlet: 3/4 in. Sanitary FlangeMax Operating Pressure: 80 psi @ 25 °C | description Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF)Inlet: 1-1/2 in. Sanitary FlangeOutlet: 1-1/2 in. Sanitary FlangeMax Operating Pressure: 80 psi @ 25 °C | description Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF)Inlet: 9/16 in. Hose BarbOutlet: 9/16 in. Hose BarbMax Operating Pressure: 80 psi @ 25 °C | description Chemistry: Hydrophilic Mixed Cellulose Esters / Polyvinylidene Fluoride (MCE / PVDF)Inlet: 3/4 in. Sanitary FlangeOutlet: 3/4 in. Sanitary FlangeMax Operating Pressure: 80 psi @ 25 °C |
| pore size 0.45 μm | pore size 0.45 μm | pore size 0.45 μm | pore size 0.45 μm |
| filtration area 0.69 m2 | filtration area 0.69 m2 | filtration area 0.69 m2 | filtration area 0.69 m2 |
| product line Opticap® XL 10 | product line Opticap® XL 10 | product line Opticap® XL 10 | product line Opticap® XL 10 |
| technique(s) bioburden reduction: suitable | technique(s) bioburden reduction: suitable | technique(s) bioburden reduction: suitable | technique(s) bioburden reduction: suitable |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
| manufacturer/tradename Opticap® | manufacturer/tradename Opticap® | manufacturer/tradename Opticap® | manufacturer/tradename Opticap® |
Still not finding the right product?
Explore all of our products under Opticap® XL 10 CapsuleMedia: Durapore® 0.45 µm
Zgodność z GMP dzięki programowi Emprove®
Przyspiesz kwalifikacje, zachowaj zgodność i oszczędzaj czas dzięki Emprove® Dossiers.
Uwaga: zostaniesz przeniesiony do EmproveSuite.com. Twoja nazwa użytkownika i hasło są niezależne od SigmaAldrich.com i mogą się różnić.
Zarejestruj się za darmo i uzyskaj dostęp do Emprove® Dossiers w ciągu kilku minut. Uaktualnij swój plan subskrypcji, aby odblokować zaawansowaną i spersonalizowaną zawartość w Emprove® Suite.
Nie znalazłeś tego, czego szukasz? Odwiedź stronę pomocy programu Emprove®..
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Masz trudności ze znalezieniem produktu lub numeru serii/partii?
Jak znaleźć numer produktu
Podczas wyświetlania na stronie internetowej numery produktów są łączone z wielkością przesyłki / ilością (przykład: T1503-25G). Pamiętaj że w polu „Numer produktu” należy podać TYLKO numer produktu (przykład: T1503).
Przykład:
Przykłady dodatkowe:
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
wpisz jako 1.000309185)
Mieć kłopoty? Poczuj się swobodnie w kontakcie Pomoc techniczna dla wsparcia