CHGL73TP3
Multilayer Durapore® 0.45/0.22 µm, Cartridge
pore size 0.45/0.22 μm, cartridge nominal length 30 in. (75 cm), Code 7 (2-226; O-rings w/locking-tabs)
Synonim(y):
Durapore Cartridge Filter 30 in. 0.45/0.22 μm Code 7
Wybierz wielkość
23 392,00 zł
Przewidywany termin wysyłki11 sierpnia 2025Szczegóły
Wybierz wielkość
About This Item
23 392,00 zł
Przewidywany termin wysyłki11 sierpnia 2025Szczegóły
Polecane produkty
Materiały
PVDF
polypropylene
polypropylene support
silicone seal
Poziom jakości
zgodność regionalna
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterylność
non-sterile
Kompatybilność ze sterylizacją
autoclavable compatible
steam-in-place compatible
linia produktu
Durapore®
Właściwości
hydrophilic
producent / nazwa handlowa
Durapore®
Parametry
≤32.4 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
0.35 bar max. differential pressure (5 psid) at 135 °C (Forward)
0.35 bar max. inlet pressure (5 psi) at 135 °C (Forward)
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
1.7 bar max. inlet pressure (25 psi) at 80 °C (Forward)
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
3.5 bar max. inlet pressure (50 psi) at 25 °C (Reverse; Intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)
metody
sterile filtration: suitable
Długość
30 in.
Szerokość
2.7 in.
długość nominalna kartridża
30 in. (75 cm)
Średnica
6.9 cm (2.7 in.)
powierzchnia filtracyjna
1.65 m2
zanieczyszczenia
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matryca
Multilayer Durapore®
pore size
0.45/0.22 μm pore size
moc wejściowa
sample type liquid
punkt pęcherzykowania
≥3450 mbar (50 psig), air with water at 23 °C
kod wkładu
Code 7 (2-226; O-rings w/locking-tabs)
Opis ogólny
Inne uwagi
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Uwaga dotycząca przygotowania
30 SIP cycles of 30 min @ 135 °C; 30 autoclave cycles of 60 min @ 126 °C
Komentarz do analizy
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 16 L per 10-inch cartridge, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Informacje prawne
Czym jest program Emprove®?
Program Emprove® jest systemem zapewniającym kompleksową i dokładną dokumentację naszych filtrów i komponentów jednorazowego użytku, surowców farmaceutycznych oraz materiałów wsadowych.
Bezpłatnie – Zaloguj się, aby pobrać
Dostępne w ramach subskrypcji lub za opłatą
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Active Filters
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej