Przejdź do zawartości
Merck
Wszystkie zdjęcia(1)

Dokumenty

CGW372S48

Millipore

Polysep II 1.0/0.2 µm nominal, Cartridge

cartridge nominal length 20 in. (50 cm), filter diam. 2.8 in.

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
23151806

Materiały

borosilicate glass fiber (BGF) membrane
mixed cellulose esters (MCE) membrane
polypropylene device
polypropylene support (spun bonded)
silicone seal

Poziom jakości

zgodność regionalna

meets FDA 21 CFR 177–182 (all component materials)

sterylność

non-sterile

Kompatybilność ze sterylizacją

autoclavable compatible
steam-in-place compatible

linia produktu

Polysep

Właściwości

hydrophilic

producent / nazwa handlowa

Polysep II

Parametry

3.5 bar max. differential pressure (50 psid) at 25 °C

metody

prefiltration: suitable

Długość

20 in.

Szerokość

2.7 in.

długość nominalna kartridża

20 in. (50 cm)

device size

20 in.

śr. filtra

2.8 in.

filter filtration area

0.92 m2

zanieczyszczenia

≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

macierz

Polysep II

pore size

1.0/0.2 μm nominal pore size
1.0/0.2 μm pore size

kod wkładu

Code 7

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Powiązane kategorie

Opis ogólny

Device Configuration: Cartridge
Cartridge Type: Liquid
Filter Grade: Prefilter

Zastosowanie

mAb & r-protein intermediates; Plasma; Vaccines & viral vectors; SVPs LVPs; Cell Culture; Media Filtration; Colloid Removal; Lipid Removal

Cechy i korzyści

Format: Double Layer

Opakowanie

Double Easy-Open bag

Uwaga dotycząca przygotowania

Sanitization: 30 min with hot water at 80 °C
Sterilization Method: 10 autoclave cycles or SIP at 121 °C for 30 min
This product was manufactured with a Millipore® media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Komentarz do analizy

After autoclaving and a 24 hour soak in ASTM® Type 1 reagent grade water at controlled room temperature, extractables level was ≤140 mg per 10-inch element after a 5000 mL flush.
Cartridges meet the requirements of the USP Oxidizable Substances Test after a water flush of 5000 mL per 10 inch Element

Inne uwagi

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer first page of Visual Inspection Guide and introduction section of Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

The product is manufuactured in a facility with a Quality Management System approved by an accredited registering body to an ISO 9001 Quality Systems Standard.

Informacje prawne

ASTM is a registered trademark of American Society for Testing and Materials
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
Polysep is a trademark of Sigma-Aldrich Co. LLC

Not finding the right product?  

Try our Narzędzie selektora produktów.

Piktogramy

Flame

Hasło ostrzegawcze

Danger

Zwroty wskazujące rodzaj zagrożenia

Zwroty wskazujące środki ostrożności

Klasyfikacja zagrożeń

Flam. Sol. 1

Kod klasy składowania

4.1B - Flammable solid hazardous materials

Klasa zagrożenia wodnego (WGK)

WGK 2


Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej