Przejdź do zawartości
Merck

Przejdź do

APFC03700

Glass Fiber Membrane Filter, 1.2 μm Pore Size

Millipore, filter diam. 37 mm, hydrophilic

Synonim(y):

Glass Fiber Filter without binder

Zaloguj się, aby wyświetlić ceny organizacyjne i kontraktowe.

Wybierz wielkość

Zmień widok
Do Państwa/SKUDostępnośćCena netto
100 filters
Sprawdź dostępność w koszyku
425,00 zł
361,25 zł

Informacje o tej pozycji

UNSPSC Code:
40161507
NACRES:
NB.24
eCl@ss:
32031602
Pore size:
1.2 μm pore size
Material:
glass fiber membrane, plain filter, white filter
Feature:
hydrophilic
Diam.:
37 mm

361,25 zł

Cena katalogowa425,00 złZaoszczędź 15%

Sprawdź dostępność w koszyku

Pomoc techniczna
Potrzebujesz pomocy? Nasz zespół doświadczonych naukowców chętnie Ci pomoże.
Pozwól nam pomóc


Quality Segment

material

glass fiber membrane, plain filter, white filter

description

1.2 um pore size, hydrophilic binderless glass fiber, 37 mm diameter

feature

hydrophilic

manufacturer/tradename

Millipore

parameter

1.2 mL/min-cm2 water flow rate, 500 °C max. temp.

diam.

37 mm

filter diam.

37 mm

thickness

240 μm

pore size

1.2 μm pore size

shipped in

ambient

General description

Filter Code: APFC
Filter Type: Depth filter
Overview
Millipore fibrous disc filters are available in a wide range of flow rates and throughput capacities. Our Glass Fiber filters are available with or without binder resins and can be sterilized by EO, gamma, or autoclave (121 °C at 1 bar).

Glass Fiber Filters with Binder Resin:
Millipore filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated liquids. They are also widely used for clarification of aqueous solutions.

Type AP15
•Lowest dirt-holding capacity
•Recommended prefilter for 0.2 to 0.6 µm filters

Type AP20
•Lower retention, higher dirt-holding capacity than AP15 filters
•Recommended prefilter for 0.8 to 8.0 µm filters
•Use upstream to protect type AP15 filters

Type AP25
•Added thickness yields same retention and greater dirt-holding capacity as AP20
•Recommended prefilter for 0.9 to 8 µm filters, especially for proteinaceous and heavily contaminated liquids
•Use upstream to protect type AP15 filters

Glass Fiber Filters without Binder Resin:
The filters without binder resin retain their structural integrity without weight loss when heated up to 500 °C and can therefore be used in gravimetric analysis as well as for the filtration of hot gases.

Type APFA
•Retains fine particles with good efficiency, even at high flow rates
•Recommended for monitoring wastewater and collecting suspended particles in gases (e.g., fumes from chimneys)
•Use in biochemical applications (e.g., collection of cells and filtration of protein or nucleic acid precipitates)

Type APFB
•Higher mechanical strength when wet and greater loading capacity than type APFA filters
•Use for liquid clarification, quantification of solids in suspensions of fine particles, and scintillation counting

Type APFC
•Greater retention, especially for fine particulate and microorganism removal than type APFA filters
•Use for determining total suspended solids in drinking water
•Use for filtering proteins or nucleic acid TCA precipitates and for collecting cells and microorganisms

Type APFD
•Thick filter with high flow and low retention
•Use for clarifying suspensions containing particulates greater than 1.0 µm

Type APFF
•Use for filtering extremely fine precipitates such as protein, nucleic acids, or serum precipitates
•Recommended for USEPA method 1311 for TCLP analysis

Type AP40
•Recommended for Standard Methods Total Suspended Solids 2540D
•Recommended for USEPA method 1311 for TCLP analysis
•Maintains structural integrity without weight loss when ignited to 550 °C (1022 °F) after sample filtration
•Recommended for determining volatile suspended matter in wastewater and industrial effluents

Application

  • Removal of fine particles and microorganisms
  • Determining total suspended solids
  • Filtering proteins or nucleic acid TCA precipitates
  • Collecting cells and microorganisms
  • Microplastics analysis grade water
  • Microplastics analysis

Other Notes

Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: General laboratory filtration
  • Intended Use: Retention or removal of biological contaminants
  • Instructions for Use: Sterilizing filtration of a liquid through a membrane with a 0.2 μm (or smaller) pore size effectively removes biological contaminants, including bacteria, mold and yeast. For the selective retention of larger biological contaminents, liquid filtration through membranes with 0.45 μm (or larger) pore sizes may be used to trap and support microorganism growth for subsequent culture and analysis
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Ta strona może zawierać tekst przetłumaczony maszynowo.

Porównaj podobne pozycje

Wyświetl pełne porównanie

Pokaż różnice

1 of 1

Ta pozycja
APFC09050APFC02500AP4001000
pore size

1.2 μm pore size

pore size

1.2 μm pore size, 90 % porosity

pore size

1.2 μm pore size, 90 % porosity

pore size

0.7 μm pore size, 90 % porosity

material

glass fiber membrane, white filter, plain filter

material

glass fiber membrane, plain filter, white filter

material

glass fiber membrane, plain filter, white filter

material

glass fiber membrane, plain filter, white filter

manufacturer/tradename

Millipore

manufacturer/tradename

Millipore

manufacturer/tradename

Millipore

manufacturer/tradename

Millipore

parameter

1.2 mL/min-cm2 water flow rate, 500 °C max. temp.

parameter

1.2 mL/min-cm2 water flow rate, 500 °C max. temp.

parameter

1.2 mL/min-cm2 water flow rate, 500 °C max. temp.

parameter

>300 mL/min-cm2 water flow rate (at 27 in Hg), 550 °C max. temp.

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

description

1.2 um pore size, hydrophilic binderless glass fiber, 37 mm diameter

description

1.2 µm pore size, hydrophilic glass fiber, 90 mm diameter

description

1.2 µm pore size, hydrophilic glass fiber, 25 mm diameter

description

0.7 µm pore size, hydrophilic glass fiber, 10 mm diameter


Still not finding the right product?


Klasa składowania

10-13 - German Storage Class 10 to 13



Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumenty section.

Proszę o kontakt, jeśli potrzebna jest pomoc Obsługa Klienta

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów



Questions

Reviews

No rating value

Active Filters