Skip to Content
Merck
All Photos(1)

Documents

F2637

Sigma-Aldrich

Ficoll® 400

BioXtra, for molecular biology, lyophilized powder

Synonym(s):

Polysucrose 400, Ficoll 400

Sign Into View Organizational & Contract Pricing


About This Item

CAS Number:
MDL number:
UNSPSC Code:
12352200
NACRES:
NA.52

biological source

non-animal source

grade

Molecular Biology
for molecular biology

product line

BioXtra

form

lyophilized powder

foreign activity

DNase (Exonuclease), NICKase (Endonuclease), RNase and Protease, none detected

storage temp.

room temp

Looking for similar products? Visit Product Comparison Guide

General description

Ficoll® 400 is a non-ionic synthetic polymer of sucrose used for cell separation and organ isolation.

Application

Suitable for
  • hybridization experiments to reduce non-specific binding of labeled probes to the membrane
  • preparation of DNA loading buffer (15% Ficoll®, 0.25% bromophenol blue and 0.25% xylene cyanol FF
  • separation of cells with similar density but different size (PBMC from human peripheral blood, bone marrow and umbilical cord blood)
  • producing density gradients to separate subcellular components
  • vitrification of cell and tissue samples.
  • to compare the effect of different perfusates on Hypoxic pulmonary vasoconstriction (HPV).
Used for cell separation and organelle isolation.

Features and Benefits

  • free from DNases, RNases, phosphatases and proteases
  • preserves functional and morphological integrity of the separated cells

Other Notes

A nonionic synthetic polymer of sucrose.

Legal Information

Ficoll is a registered trademark of Cytiva

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Customers Also Viewed

Hae Young Yoo et al.
Pulmonary circulation, 3(2), 396-405 (2013-09-10)
Hypoxic pulmonary vasoconstriction (HPV) is a compensatory physiological mechanism in the lung that optimizes the matching of ventilation to perfusion and thereby maximizes gas exchange. Historically, HPV has been primarily studied in isolated perfused/ventilated lungs; however, the results of these
Cristina Batlle et al.
Cell reports, 30(4), 1117-1128 (2020-01-30)
Prion-like proteins form multivalent assemblies and phase separate into membraneless organelles. Heterogeneous ribonucleoprotein D-like (hnRNPDL) is a RNA-processing prion-like protein with three alternative splicing (AS) isoforms, which lack none, one, or both of its two disordered domains. It has been
Gaye Cetinkaya et al.
Cryobiology, 63(3), 292-297 (2011-10-25)
Preservation of cell and tissue samples from endangered species is a part of biodiversity conservation strategy. Therefore, setting up proper cell and tissue cryopreservation methods is very important as these tissue samples and cells could be used to reintroduce the
Ivana Gessara et al.
Stem cell reports, 16(4), 784-796 (2021-03-20)
The ability to genetically manipulate organisms has led to significant insights into functional genomics in many species. In birds, manipulation of the genome is hindered by the inaccessibility of the one-cell embryo. During embryonic development, avian primordial germ cells (PGCs)
Zhaoming Yang et al.
Frontiers in endocrinology, 11, 587450-587450 (2020-12-29)
Islet culture prior to transplantation is a standard practice in many transplantation centers. Nevertheless, the abundant islet mass loss and function impairment during this serum-deprivation culture period restrain the success of islet transplantation. In the present study, we used a

Articles

Centrifugation enables the separation of particles by sedimentation. Learn how to separate particles using a centrifuge and how to use Stokes' law to calculate the velocity of sedimentation.

Centrifugation enables the separation of particles by sedimentation. Learn how to separate particles using a centrifuge and how to use Stokes' law to calculate the velocity of sedimentation.

Centrifugation enables the separation of particles by sedimentation. Learn how to separate particles using a centrifuge and how to use Stokes' law to calculate the velocity of sedimentation.

Centrifugation enables the separation of particles by sedimentation. Learn how to separate particles using a centrifuge and how to use Stokes' law to calculate the velocity of sedimentation.

Protocols

Ficoll 400® is a non-ionic polymer with high hydrophilicity and water solubility, suitable for various biological applications.

Ficoll 400® is a non-ionic polymer with high hydrophilicity and water solubility, suitable for various biological applications.

Ficoll 400® is a non-ionic polymer with high hydrophilicity and water solubility, suitable for various biological applications.

Ficoll 400® is a non-ionic polymer with high hydrophilicity and water solubility, suitable for various biological applications.

See All

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service