346764
Poly(vinyl chloride)
average Mw ~233,000, average Mn ~99,000
Synonym(s):
PVC
Sign Into View Organizational & Contract Pricing
All Photos(3)
About This Item
Recommended Products
form
powder
mol wt
average Mn ~99,000
average Mw ~233,000
inherent viscosity
1.40(lit.)
density
1.4 g/mL at 25 °C (lit.)
application(s)
battery manufacturing
storage temp.
2-8°C
SMILES string
ClC=C
InChI
1S/C2H3Cl/c1-2-3/h2H,1H2
InChI key
BZHJMEDXRYGGRV-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Personal Protective Equipment
dust mask type N95 (US), Eyeshields, Gloves
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
PloS one, 7(11), e50212-e50212 (2012-12-05)
Although oxygen is essential for the wound healing process, tissue hypoxia is known to stimulate angiogenesis. To explore these inconsistent findings, we estimated the influence of the oxygen environment on wound healing with our original model. Experiment 1 (Establishment of
Environmental science and pollution research international, 20(5), 3086-3097 (2012-10-12)
The construction and electrodes characteristics of poly(vinylchloride) (PVC)-based polymeric membrane electrode (PME) and coated graphite electrode (CGE), incorporating 1,3-alternate thiacalix[4]crown as ionophore for estimation of Hg(II) ions, are reported here. The best potential response was observed for PME-1 having membrane
The Journal of the Acoustical Society of America, 132(4), EL323-EL328 (2012-10-09)
Results of laboratory measurements of sound transmission through 5 × 10 arrays of meter long polyvinyl chloride pipes with lattice constants of 5 and 10 cm with filling fractions of 13% and 50% located either on medium density fibreboard or
Molecular imaging, 12(1), 28-38 (2013-01-26)
At present, there is considerable interest in the use of in vivo fluorescence and bioluminescence imaging to track the onset and progression of pathologic processes in preclinical models of human disease. Optical quantitation of such phenomena, however, is often problematic
Gigiena i sanitariia, (1)(1), 42-46 (2013-06-29)
In the article the issues of environmental, sanitary and hygienic safety of medical waste management are considered. Recently, for the treatment of certain types of medical waste thermal methods using small plants not equipped with a proper flue gas cleaning
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service