Saltar al contenido
Merck

15614

Sigma-Aldrich

Hexamethylenetetramine

meets analytical specification of Ph. Eur., BP, 99-100.5% (calc. to the dried substance)

Sinónimos:

1,3,5,7-Tetraazatricyclo[3.3.1.13,7]decane, Hexamine, Methenamine, Urotropine

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C6H12N4
Número de CAS:
Peso molecular:
140.19
Beilstein/REAXYS Number:
2018
EC Number:
MDL number:
UNSPSC Code:
12352116
PubChem Substance ID:
NACRES:
NA.21

vapor pressure

<0.01 mmHg ( 20 °C)

Quality Level

assay

99-100.5% (calc. to the dried substance)

form

solid

autoignition temp.

770 °F

quality

meets analytical specification of Ph. Eur., BP

impurities

acidic and alkalic reac. substances, complies
residual solvents, in accordance
≤0.002% heavy metals (as Pb)
≤0.005% free formaldehyde

loss

≤2% loss on drying

mp

280 °C (subl.) (lit.)

solubility

H2O: soluble

anion traces

chloride (Cl-): ≤100 mg/kg
sulfate (SO42-): ≤100 mg/kg

suitability

complies for appearance of solution

application(s)

pharmaceutical (small molecule)

SMILES string

C1N2CN3CN1CN(C2)C3

InChI

1S/C6H12N4/c1-7-2-9-4-8(1)5-10(3-7)6-9/h1-6H2

Inchi Key

VKYKSIONXSXAKP-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Pictograms

FlameExclamation mark

signalword

Warning

hcodes

Hazard Classifications

Flam. Sol. 2 - Skin Sens. 1B

Storage Class

4.1B - Flammable solid hazardous materials

wgk_germany

WGK 1

flash_point_f

482.0 °F - closed cup

flash_point_c

250 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Enhanced quantum dot deposition on ZnO nanorods for photovoltaics through layer-by-layer processing.
<BIG>Joe Briscoe</BIG>
Journal of Materials Chemistry, 2517-2523 (2011)
E M Rodríguez et al.
Histochemistry, 81(3), 253-263 (1984-01-01)
The use of butyl-methyl-methacrylate embedding and the application of the silver methenamine (SM) method as a poststaining of the immunoperoxidase-DAB (IP) procedure led to the standardization of several useful methods for the visualization of tissue antigens at the light and
Jianguo Hu et al.
Talanta, 93, 345-349 (2012-04-10)
A green, one-step method for synthesis of graphene-Au nanoparticles (graphene-AuNPs) was introduced in this article, using an environmentally benign hexamethylenetetramine (HMTA) as reducing and stabilizing agent. HMTA slowly was hydrolyzed to generate aldehyde ammonia to reduce graphene oxides (GO) and
Ann Pontén et al.
Contact dermatitis, 68(1), 50-53 (2012-10-06)
The currently used patch test concentration for formaldehyde is 1.0% (wt/vol) in water. However, clinical experience and previous studies suggest that 1.0% might be insufficient for detecting an optimized number of clinically relevant cases of contact allergy to formaldehyde. To
Erin M Warshaw et al.
Journal of the American Academy of Dermatology, 66(2), 229-240 (2011-05-21)
Relatively little is known about the epidemiology of allergic contact dermatitis in older individuals. We sought to determine the frequency of positive and clinically relevant patch test reactions in older individuals (≥ 65 years old) referred for patch testing, and

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico