Saltar al contenido
Merck
Todas las fotos(1)

Key Documents

44690-U

Supelco

Glyphosate solution

certified reference material, 1000 μg/mL in H2O

Sinónimos:

Glyphosate solution, N-(Phosphonomethyl)glycine

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
77101502
NACRES:
NA.24

grade

certified reference material
TraceCERT®

agency

EPA 547

product line

TraceCERT®

CofA

current certificate can be downloaded

feature

standard type calibration

packaging

ampule of 1 mL

concentration

1000 μg/mL in H2O

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

application(s)

agriculture
environmental

format

multi-component solution

storage temp.

2-8°C

¿Está buscando productos similares? Visita Guía de comparación de productos

General description

US EPA 500 Series methods are analytical methods for identifying and quantifying organic contaminants such as volatile organic compounds (VOCs), pesticides, synthetic organic compounds (SOCs), and trihalomethane disinfection byproducts (THMs) in raw source water, finished drinking water, and drinking water at all stages of treatment. For ISO/IEC 17025 accredited labs, it is important to show traceability of all results, so for calibration, certified reference materials (CRMs) must be used. Our rapidly expanding “TraceCERT” product range includes an increasing number of CRMs for pesticides. These products are manufactured according to ISO/IEC 17025 and ISO Guide 34 double accreditation, which is the highest achievable quality level for reference material producers and which is also referred to as “the gold standard”. The CRM solutions are produced gravimetrically using NIST traceable weights for balance calibration.

Application

EPA 547 Glyphosate Solution is used as a CRM to quantify the broad-spectrum herbicide glyphosate in beer samples by an electrochemical assay based on anti-glyphosate-antibody-modified magnetic beads and disposable electrochemical sensors.
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Other Notes

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Legal Information

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage Class

10 - Combustible liquids

wgk_germany

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, multi-purpose combination respirator cartridge (US)


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Slide 1 of 1

1 of 1

Glyphosate determination by coupling an immuno-magnetic assay with electrochemical sensors
Bettazzi F, et al.
Sensors, 18(9), 2965-2965 (2018)

Protocolos

EPA Method 547 outlines the analysis of glyphosate in drinking water by direct aqueous injection HPLC, post column derivatization, and fluorescence detection

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico