Saltar al contenido
Merck

13979-U

Supelco

Metal Packed GC Column (General Configuration)

phase none, matrix 80/100 Porapak Q support, L × O.D. × I.D. 10.0 ft (3.0 m) × 1/8 in. × 2.1 mm

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
41115710
NACRES:
SB.54
En este momento no podemos mostrarle ni los precios ni la disponibilidad

Materiales

stainless steel column

Nivel de calidad

Parámetros

0-250 °C temperature (isothermal or programmed)

técnicas

gas chromatography (GC): suitable

L × D.I. × D.E.

10.0 ft (3.0 m) × 1/8 in. × 2.1 mm

Matriz

80/100 Porapak Q support

grupo activo de la matriz

none phase

tipo de columna

packed GC

compatibilidad

for use with General Configuration

Descripción general

An economical metal column should be used for less demanding applications where the inertness of glass is not required. This column is of a general configuration, and can be carefully bent to fit most instruments.
Packed column made up of stainless steel are basically used when higher carrier gas flow rates are employed as they can sustain elevated pressure. Stainless steel columns are usually washed with dilute hydrochloric acid, then with water followed by methanol, acetone, methylene dichloride and n-hexane in order to remove any corrosion products and traces of lubricating agents.[1]

Aplicación

Porapak Q packed in a stainless steel gas chromatographic column maybe used for the oxidation reduction experiments in order to design the appropriate surface sites for ruthenium-ceria catalysts supported on graphite by controlled preparation method.[2]

Código de clase de almacenamiento

11 - Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Scientific Bases for the Preparation of Heterogeneous Catalysts.
Gaigneaux E
Science, 751-752 (2010)
Introduction to Analytical Gas Chromatography.
Scott PW.
Science, 102-108 (1997)

Questions

1–2 of 2 Questions  
  1. How do I properly condition Product No. 13979-U, SS Column 10ft General Coil 80/100 Porapak Q?

    1 answer
    1. Polymers continuously shrink with heat due to loss of residual monomer. If conditioned too harshly, rapid loss of residual monomer results in gaps through the column.  By mildly conditioning the polymer packing, it helps to decrease the number and size of voids due to shrinkage of the polymer.   Below is a suggested conditioning procedure for polymer packed columns.  Ramp rate is not important compared to the temperature for the analysis.  Flow rate of 5-20 deg C/minute can be use if desired, once the column has been conditioned.  120 deg C for 4 hours  160 deg C for 4 hours  180 deg C for 4 hours  200 deg C for 4 hours  220 deg C for 4 hours  @ 60 mL/minute.

      Helpful?

  2. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.