Saltar al contenido
Merck
Todas las fotos(1)

Key Documents

SCC295

Sigma-Aldrich

hERG1a/1b Inducible HEK293 Cell Line

Human

Sinónimos:

hERG1a/1b Inducible HEK293 Cell Line

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41106514
NACRES:
NA.71

product name

hERG1a/1b Inducible HEK293 Cell Line,

biological source

human

packaging

pkg of >1X10⁶ vials

manufacturer/tradename

Sigma-Aldrich

growth mode

N/A

technique(s)

cell culture | mammalian: suitable

shipped in

dry ice

storage temp.

≤ − 140°C

General description

HERG channel inhibition assays for preclinical cardiac safety screening of new drug compounds use electorphysiological methodology and employ hERG-expressing recombinant cell lines. Despite evidence that the cardiac IKr potassium current is produced by heteromeric hERG1a/1b channels1, 2, 3, drug screening assays have long relied on homomeric hERG1a alone, because of the instability of hERG 1b expression in so-called “stable” recombinant cell lines4. The novel inducible hERG1a/1b heteromeric cell line offers an improved tool for preclinical cardiac toxicity screening, by enabling more accurate predictions of off-target drug effects on cardiac IKr, particularly in computational models relying on accurate IC50 measurements. hERG1a/1b cells also can facilitate the study of heteromeric assembly of the hERG 1a and 1b subunits during biogenesis.5

Application

HERG channel inhibition assays for preclinical cardiac safety screening of new drug compounds use electorphysiological methodology and employ hERG-expressing recombinant cell lines. Despite evidence that the cardiac IKr potassium current is produced by heteromeric hERG1a/1b channels1, 2, 3, drug screening assays have long relied on homomeric hERG1a alone, because of the instability of hERG 1b expression in so-called “stable” recombinant cell lines4. The novel inducible hERG1a/1b heteromeric cell line offers an improved tool for preclinical cardiac toxicity screening, by enabling more accurate predictions of off-target drug effects on cardiac IKr, particularly in computational models relying on accurate IC50 measurements. hERG1a/1b cells also can facilitate the study of heteromeric assembly of the hERG 1a and 1b subunits during biogenesis.5 Source The heteromeric hERG1a/1b Inducible HEK293 cell line, in which hERG1b protein expression is tightly controlled by doxycyclin dose and treatment time, was derived from a homomeric hERG 1a expressing HEK293 cell line.5 References1. J Biol Chem 2004, 279(43): 44690–446942. Circ Res 2008, 103(7): e81–e953. PNAS 2014, 111(50): 18073-180774. Br J Pharmacol 2011, 164(2b): 419-432. 5. Biophysical J 2018, Volume 114, Issue 3, Suppl 1, 2 (292a) (Poster Abstract)
• Each vial contains ≥ 1X10⁶ viable cells.• Cells are tested negative for infectious diseases by a Human Essential CLEAR panel by Charles River Animal Diagnostic Services.• Cells are verified to be of human origin and negative for inter-species contamination from mouse, rat, chinese hamster, Golden Syrian hamster, and Non-human Primate (NHP) as assessed by a Contamination Clear panel by Charles River Animal Diagnostic Services• Cells are negative for mycoplasma contamination.

Features and Benefits

The heteromeric hERG1a/1b Inducible HEK293 cell line, in which hERG1b protein expression is tightly controlled by doxycyclin dose and treatment time, was derived from a homomeric hERG 1a expressing HEK293 cell line

Storage and Stability

The cells should be stored in liquid nitrogen until use. The cells can be cultured for at least 10 passages after initial thawing without significantly affecting functionality.

Other Notes

This product is intended for sale and sold solely to academic institutions for internal academic research use per the terms of the “Academic Use Agreement” as detailed in the product documentation. For information regarding any other use, please contact licensing@emdmillipore.com.

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Storage Class

12 - Non Combustible Liquids

wgk_germany

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico