Skip to Content
Merck
  • Use of multivariate statistical techniques to optimize the separation of 17 capsinoids by ultra performance liquid chromatography using different columns.

Use of multivariate statistical techniques to optimize the separation of 17 capsinoids by ultra performance liquid chromatography using different columns.

Talanta (2015-01-27)
Janclei P Coutinho, Gerardo F Barbero, Oreto F Avellán, A Garcés-Claver, Helena T Godoy, Miguel Palma, Carmelo G Barroso
ABSTRACT

In this work a multivariate statistical tool (Derringer and Suich optimization) was proposed for the separation of seventeen capsinoids (natural and synthetic) using the UHPLC-DAD chromatography. Capsinoids were analyzed at 280 nm. The variables optimized were the mobile phase (water (0.1% acetic acid as solvent A) and acetonitrile (0.1% as solvent B)), gradient time and flow rate. Two columns with different length (50 and 100 mm) were used for the chromatographic separation. The two columns used properly separated the seventeen capsinoids, however the 100 mm column length showed a better chromatographic separation with a shorter run time and smaller peak widths. These results provided better values of limit of detection and quantification for the 100 mm column length. The better conditions of separation with the 100 mm column length were established with: initial mobile phase with 41.8% of solvent B; 3.96 min of linear gradient time to reach 100% of solvent B; flow rate of 0.679 mL min(-1). A validation of the method has been done with excellent values of repeatability (RSD<1.92) and intermediate precision (RSD<3.92). The developed method has been applied to real samples. Capsiate has been identified and quantified in some varieties of peppers.

MATERIALS
Product Number
Brand
Product Description

Supelco
Residual Solvent - Toluene, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ethyl acetate
Sigma-Aldrich
Ethyl acetate
Sigma-Aldrich
Ultrapure Acetonitrile
Sigma-Aldrich
Ethyl acetate, ACS reagent, ≥99.5%
Sigma-Aldrich
Toluene, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethyl acetate, biotech. grade, ≥99.8%
Sigma-Aldrich
Ethanol, purum, absolute ethanol, denaturated with 2% 2-butanone, A15 MEK1, ≥99.8% (based on denaturant-free substance)
Sigma-Aldrich
Ethanol, purum, fine spirit, denaturated with 4.8% methanol, F25 METHYL1, ~96% (based on denaturant-free substance)
Supelco
Ethyl Acetate, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Residual Solvent - Chloroform, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Sodium nitrite, analytical standard
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
USP
Glacial acetic acid, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Toluene, ACS reagent, ≥99.5%
Sigma-Aldrich
Toluene, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethyl acetate, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Ethyl acetate, suitable for HPLC, ≥99.7%
Millipore
Bifido Selective Supplement B, suitable for microbiology
Supelco
5α-Androstan-17β-ol-3-one, VETRANAL®, analytical standard
Sigma-Aldrich
Pentadecanoic acid, 99%
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Ethanol, tested according to Ph. Eur.
Sigma-Aldrich
Ethanol, for residue analysis
Sigma-Aldrich
Hexanoyl chloride, 97%
Supelco
Hexane, analytical standard
Supelco
Ethyl acetate, analytical standard
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, purum, ≥99.0% (TLC)
Supelco
Toluene, analytical standard