HPLC Analysis of Withania Extract on Ascentis® Express Phenyl-Hexyl

application for HPLC

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

técnicas

HPLC: suitable

parámetros analíticos

column: Ascentis Express Phenyl-Hexyl, 10 cm x 2.1 mm I.D., 2.7 μm particles (53336-U)
mobile phase: [A] water; [B] acetonitrile
gradient: 20 to 100% B in 10 min; held at 100% B for 0.5 min
flow rate: 0.3 mL/min
pressure: 160 bar (2320 psi)
column temp.: 35 °C
detector: UV, 227 nm
injection: 5 μL
sample: 20 mg/mL in water:acetonitrile (50:50); sonicate 15 minutes; filter 0.45 μm;
dilute to water:acetonitrile (80:20)

idoneidad

application for HPLC

aplicaciones

vitamins, nutraceuticals, and natural products

Nota de análisis

This application demonstrates the suitability of Ascentis Express Phenyl-Hexyl for the efficient separation of withania extract.

Información legal

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany

Analito

Descripción

    Withanoside IV
    Withanoside V
    Withaferin A
    12-Deoxywithastramonolide
    Withanolide A
    Withanone
    Withanolide B

Estándar

Referencia del producto
Descripción
Precios

columna analítica


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico