If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
MAK044
kit de cuantificación de ácidos grasos libres
sufficient for 100 colorimetric or fluorometric tests
Sinónimos:
Kit de ensayo de ácidos grasos libres
About This Item
Productos recomendados
uso
sufficient for 100 colorimetric or fluorometric tests
aplicaciones
cosmetics
food and beverages
método de detección
colorimetric
fluorometric
enfermedades relevantes
endocrinological disorders, diabetes; cancer
temp. de almacenamiento
−20°C
Descripción general
Las anomalías en el metabolismo de los ácidos grasos producen la enfermedad osteatosis hepática.[1] La acumulación de ácidos grasos libres en los miocitos provoca el riesgo de disfunción cardiaca.[2] El aumento de la β-oxidación de los ácidos grasos está implicado en la isquemia cardiaca.[2]
Aplicación
Idoneidad
Principio
Producto relacionado
sustituido por
Palabra de señalización
Danger
Frases de peligro
Consejos de prudencia
Clasificaciones de peligro
Resp. Sens. 1
Código de clase de almacenamiento
10 - Combustible liquids
Punto de inflamabilidad (°F)
188.6 °F - closed cup
Punto de inflamabilidad (°C)
87 °C - closed cup
Elija entre una de las versiones más recientes:
Certificados de análisis (COA)
¿No ve la versión correcta?
Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
Helpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Helpful?
-
-
Is there a step in the process where samples can be preserved for future analysis using the kit?
1 answer-
Yes, samples can be preserved for future analysis using the kit by aliquoting and freezing them if needed for multiple uses. However, it's recommended to use fresh samples whenever possible to ensure accurate results. Dried lipids can be stored in 200 µl of Fatty Acid Assay Buffer at -80°C. In case of lipid precipitation, re-dissolve the lipids by sonication. However, the supplier does not specify the maximum duration for which the samples stored at -80°C will remain stable. Storing samples at -80°C may impact their stability, potentially resulting in lower than expected readings. Therefore, it is recommended to use fresh samples for this assay whenever possible to ensure accurate results.
If frozen samples are used, they should be snap frozen in liquid nitrogen immediately after collection. These samples cannot undergo multiple freeze-thaw cycles and must be stored for relatively short periods. It's important to note that stability studies on different sample types have not been conducted, so there is no advice available regarding the timeframe for measuring frozen samples.Helpful?
-
-
Can MAK044 quantify only albumin-bound free fatty acids (FFA), or does it also quantify unbound FFA?
1 answer-
The kit specifically detects unbound free fatty acids in the samples and does not detect any albumin-bound free fatty acids.
Helpful?
-
-
What are the recommended storage instructions for the Enhancer reagent and unused Assay Buffer in the MAK044 Free Fatty Acid Quantitation Kit?
1 answer-
The enhancer can be aliquoted and stored at -20°C, while the assay buffer can also be stored in aliquots at -20°C to avoid multiple freeze-thaw cycles.
Helpful?
-
-
I would like to quantify butyric acid in bacteria culture supernatant. Does this MAK044 Free Fatty Acid Quantitation Kit suitable or is there a kit you can recommend. Thank you.
1 answer-
Butyric acid is a short-chain fatty acid. This kit is suitable for detecting the long-chain free fatty acids in various biological samples, such as serum, plasma, and other body fluids, food, growth media, etc. The Short Chain Fatty Acid Kit, prod number SBR0030, offers a potential analytical option. This kit is suitable for detection of several SCFAs, including Butyric, by HPLC, LC-MS, and GC-MS. See the link below to the technical bulleting should these methods be suitable:
https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/593/831/SBR00030bul.pdfHelpful?
-
-
Can this kit be used to analyse NEFA in plasma using the Pentra C400 instrument?
1 answer-
This kit is suitable for detecting nonesterified fatty acids in plasma (NEFA). However, suitability with Pentra C400 instrument has not been determined. This application must be determined by the end-user.
Helpful?
-
-
Can these kits be used with serum samples from mouse?
1 answer-
Yes, this kit can be used on mouse serum samples. We generally recommend that fresh serum samples be used. Frozen samples can probably be used. However, the successful use of frozen samples depends on the efficiency of freezing them and the amount of time they have been frozen. If previously frozen serum samples are used, you may want to check the performance of the kit with fresh vs. frozen samples.
Helpful?
-
-
What is the Department of Transportation shipping information for this product?
1 answer-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
Helpful?
-
Active Filters
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico