KCQS00
KiCqStart® SYBR® Green qPCR ReadyMix™
For Bio-Rad, Cepheid, Eppendorf, Illumina, Corbett, and Roche systems
Sinónimos:
qPCR master mix, sybr green qPCR
About This Item
Productos recomendados
form
liquid
usage
sufficient for 1250 reactions
sufficient for 250 reactions
sufficient for 5000 reactions
feature
dNTPs included
hotstart
storage condition
protect from light
technique(s)
qPCR: suitable
color
colorless
input
purified DNA
compatibility
for use with Bio-Rad CFX384
for use with Bio-Rad CFX96
for use with Bio-Rad MJ Chromo4
for use with Bio-Rad MJ Opticon 2
for use with Bio-Rad MJ Opticon Cepheid SmartCycler
for use with Bio-Rad MiniOpticon
for use with Bio-Rad MyiQ
for use with Eppendorf® Mastercycler ep realplex2 s
for use with Eppendorf® Mastercycler ep realplex
for use with Illumina Eco qPCR
for use with Qiagen Corbett Rotor-Gene 3000
for use with Qiagen Corbett Rotor-Gene 6000
for use with Qiagen Corbett Rotor-Gene Q
for use with Roche LightCycler 480
detection method
SYBR® Green
shipped in
dry ice
storage temp.
−20°C
¿Está buscando productos similares? Visita Guía de comparación de productos
General description
Es crucial una amplificación muy específica para conseguir una qPCR satisfactoria con tecnología de colorante SYBR Green I porque este colorante se une a, y detecta, cualquier dsDNA generado durante la amplificación. La ADN polimerasa Taq de inicio en caliente es inactivada por anticuerpo antes de la etapa inicial de desnaturalización de la PCR.
Application
- Expresión génica
- Cuantificación del ADN
- CHiP
Features and Benefits
- Resultados del análisis en tan sólo 33 minutos
- Resultados de la PCR en tiempo real muy eficaces y sensibles
- Se requiere poca o ninguna optimización
Components
packaging:
250 reactions* = 2 X 1.25 mL tubes
1250 reactions* = 10 X 1.25 mL tubes
5000 reactions* = 1 X 50 mL tube
*number of reactions based on a 20uL volume
Other Notes
La mezcla KiCqStart SYBR Green qPCR ReadyMix es estable durante 1 año cuando se conserva en un refrigerador a una temperatura constante de -20°C, protegida de la luz. Para su conveniencia, puede conservarse sin congelar entre +2 y +8°C durante un máximo de 6 meses. Después de descongelar, mezcle bien antes de usar. No se recomienda congelar y descongelar repetidamente el producto. Sin embargo, se demostró que el producto no perdía rendimiento después de 20 ciclos de congelación-descongelación o 2 meses a +20°C.
Different real-time PCR systems employ different strategies for normalization of fluorescent signals and correction of well-to-well optical variations. It is critical to match the appropriate qPCR reagent to your specific instrument. KiCqStart SYBR Green qPCR ReadyMix does not contain an internal reference dye. Compatible instruments include:
- Bio-Rad® CFX384™
- Bio-Rad CFX96™
- Bio-Rad MiniOpticon™
- Bio-Rad/MJ Chromo4™
- Bio-Rad/MJ Opticon 2
- Bio-Rad/MJ Opticon™
- Cepheid SmartCycler®
- Eppendorf Mastercycler® ep realplex
- Eppendorf Mastercycler ep realplex2 s
- Illumina Eco qPCR
- Qiagen/Corbett Rotor-Gene® 3000
- Qiagen/Corbett Rotor-Gene 6000
- Qiagen/Corbett Rotor-Gene Q
- Roche LightCycler® 480
Legal Information
Optional
related product
Storage Class
12 - Non Combustible Liquids
wgk_germany
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Artículos
After a traditional PCR has been completed, the PCR/qPCR data analysis is conducted by resolution through an agarose gel or, more recently, through a capillary.
PCR assay guide navigates you through primer validation and other assay optimization factors to ensure high sensitivity and specificity for optimum DNA/ RNA quantification.
Real-time polymerase chain reaction allows researchers to estimate the quantity of starting material in a sample. It has a much wider dynamic range of analysis than conventional PCR
Protocolos
Quantitative PCR protocol using SYBR Green reagents. Procedure supports most qPCR instruments.
Optimization of qPCR conditions is important for the development of a robust assay. The two main approaches are optimization of primer concentration and/or annealing temperatures.
Analysis of gene expression data requires a stable reference or loading control. This reference is usually one or more reference genes.
SYBR Green I dye in qPCR measures target quantity, adaptable to specific needs with a standard protocol.
Contenido relacionado
SYBR® Green I, a commonly used fluorescent DNA binding dye, binds all double-stranded DNA and detection is monitored by measuring the increase in fluorescence throughout the cycle. Explore our LuminoCt® and KiCqStart® products for Fast qPCR or JumpStart™ reagents for conventional qPCR
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico