GE28-9035-31
TempliPhi™ Sequence Resolver Kit
Cytiva 28-9035-31, sufficient for 200 reactions
Seleccione un Tamaño
MXP 78,007.00
Fecha estimada de envío17 de abril de 2025
Seleccione un Tamaño
About This Item
MXP 78,007.00
Fecha estimada de envío17 de abril de 2025
Productos recomendados
form
liquid
usage
sufficient for 200 reactions
feature
hotstart: no
manufacturer/tradename
Cytiva 28-9035-31
color
colorless
shipped in
dry ice
storage temp.
−70°C
General description
The kit can be used with both small (e.g., plasmids and M13) and large (fosmids and bacterial artificial chromosomes [BACs]) circular templates. The starting template for the reaction can be purified DNA, glycerol stock, liquid culture, or colonies. The reaction takes less than 20 min to prepare and after an overnight incubation at 10° C, it is ready to be used directly in sequencing applications with the sequencing chemistry of choice. A ten microliter (10 μ) reaction typically yields 1 μg of DNA in a standard overnight reaction.
Features and Benefits
- For the amplification of difficult templates for successful DNA sequencing.
- Solve the most common sequencing problems such as repeats, sequencing stops, and compressions with a single kit.
- Improve difficult template sequencing success with up to 820 bp Phred 20 read length.
- Cultureless preparation from bacterial colonies, glycerol stock or purified DNA; saves time and reagents.
- Easy-to-use kit requires only 20 min hands-on time.
- Amplified DNA can be directly used in sequencing reactions.
- illustra™ TempliPhi™ Sequence Resolver Kit produces exceptional sequencing results from difficult templates such as those with high GC content and secondary structures.
- The kit resolves most of the sequencing stops or gaps that routinely elude other commonly used finishing methods.
Storage and Stability
Analysis Note
Legal Information
On packaging and insert for kits:
For use only as licensed by Qiagen GmbH. and Cytiva. The Phi 29 DNA polymerase may not be re-sold or used except in conjunction with the other components of this kit. See US patent numbers 5,854,033, 6,124,120, 6,143,495, 6,323,009, 5,198,543, 5,576,204, and their equivalents in other countries.
On container:
Subject to proprietary rights of Cytiva. May not be re-sold or used except with the other components of this kit. See US patent numbers 5,576,204, and their equivalents in other countries.
Storage Class
12 - Non Combustible Liquids
Elija entre una de las versiones más recientes:
Certificados de análisis (COA)
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.
Si necesita más asistencia, póngase en contacto con Atención al cliente
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico