Saltar al contenido
Merck

C9651

Sigma-Aldrich

Ammonium cerium(IV) sulfate dihydrate

≥95%

Sinónimos:

Ceric ammonium sulfate, Cerium(IV) ammonium sulfate

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
Ce(NH4)4(SO4)4 · 2H2O
Número de CAS:
Peso molecular:
632.55
MDL number:
UNSPSC Code:
12352300

assay

≥95%

mp

130 °C (lit.)

SMILES string

N.N.N.N.O.O.[Ce+4].OS([O-])(=O)=O.OS([O-])(=O)=O.OS([O-])(=O)=O.OS([O-])(=O)=O

InChI

1S/Ce.4H3N.4H2O4S.2H2O/c;;;;;4*1-5(2,3)4;;/h;4*1H3;4*(H2,1,2,3,4);2*1H2/q+4;;;;;;;;;;/p-4

InChI key

VCNAMBGKEDPVGQ-UHFFFAOYSA-J

¿Está buscando productos similares? Visita Guía de comparación de productos

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

S Kaul et al.
Amino acids, 34(2), 315-320 (2006-11-07)
An assessment of the potential of proline to scavenge free radicals was made in a couple of in vitro assay systems, namely graft co-polymerization and autooxidation of pyrogallol. Both these assays are essentially dependent upon free radical mechanisms. Graft co-polymerization
K H Gordon et al.
Organic letters, 3(1), 53-56 (2001-06-30)
[figure: see text] A novel benzyloxyaniline linker that uses ceric ammonium nitrate (CAN) as a cleavage reagent is described. Its application in the solid-phase synthesis of N-unsubstituted beta-lactams and secondary amides furnishes compounds in moderate to excellent yield (45-91%) and
K Tsuda et al.
Clinical chemistry, 41(4), 581-585 (1995-04-01)
We have modified an automated measurement system of urinary iodine (UI) and established a sensitive UI assay system by using ultraviolet (UV) digestion. The automated system is sensitive enough to detect concentrations of UI < 0.78 mumol/L (< 10 micrograms/dL)
Effect of high room temperature on urinary iodine assay.
N T Dung et al.
Clinical chemistry, 43(6 Pt 1), 1084-1085 (1997-06-01)
Babu G Gowda et al.
Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 18(6), 671-674 (2002-06-27)
Two simple and sensitive indirect spectrophotometric methods for the assay of propranolol hydrochloride (PPH) and piroxicam (PX) in pure and pharmaceutical formulations have been proposed. The methods are based on the oxidation of PPH by a known excess of standard

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico