Saltar al contenido
Merck
Todas las fotos(1)

Documentos

96665

Supelco

Potassium Standard for AAS

TraceCERT®, 1 g/L K in nitric acid (nominal concentration)

Sinónimos:

Potassium Atomic Absorption Standard

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41116107
NACRES:
NA.24

grade

certified reference material
TraceCERT®

Quality Level

product line

TraceCERT®

concentration

1 g/L K in nitric acid (nominal concentration)

technique(s)

AAS: suitable

application(s)

industrial qc
pharmaceutical

format

single component solution

General description

This certified reference material (CRM) is produced in accordance with ISO 17034 and characterized in accordance with ISO/IEC 17025. This CRM is traceable to SI unit kg and measured against primary material from a National Metrology Institute (NMI), e.g. NIST.

Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.

Download your certificate at http://www.sigma-aldrich.com to view certified values, including uncertainty and expiry date.

Application

Potassium standard has been used as a calibration standard to determine the concentration of potassium present in minced beef using atomic absorption spectrophotometry(AAS).

Analysis Note

1 g/L K in 2% nitric acid, prepared with high purity KNO3, HNO3 and water

Other Notes

For a complete product listing of our TraceCERT® range of CRMs for ICP and AAS, technical information, and example certificates please visit our ICP & AAS standards website

Legal Information

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

pictograms

Corrosion

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2

Storage Class

8B - Non-combustible corrosive hazardous materials

wgk_germany

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter


Choose from one of the most recent versions:

Certificados de análisis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Laser Induced Breakdown Spectroscopy for quantification of sodium and potassium in minced beef: a potential technique for detecting beef kidney adulteration.
Dixit Y, et al.
Analytical Methods : Advancing Methods and Applications, 9(22), 3314-3322 (2017)
Laser Induced Breakdown Spectroscopy for quantification of sodium and potassium in minced beef: a potential technique for detecting beef kidney adulteration
Dixit.Y, et al.
Analytical Methods : Advancing Methods and Applications (2017)

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico