Saltar al contenido
Merck

900667

Sigma-Aldrich

Acetonitrilo

≥99.92%, suitable for mass spectrometry (MS), UHPLC

Sinónimos:

ACN, Cianometano, Cianuro de metilo, Nitrilo de etilo

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

100 ML
MXP 2,667.00
250 ML
MXP 2,947.00
1 L
MXP 8,914.00
4 X 4 L
MXP 61,944.00

MXP 2,667.00


Check Cart for Availability

Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
100 ML
MXP 2,667.00
250 ML
MXP 2,947.00
1 L
MXP 8,914.00
4 X 4 L
MXP 61,944.00

About This Item

Fórmula lineal:
CH3CN
Número de CAS:
Peso molecular:
41.05
Beilstein:
741857
Número CE:
Número MDL:
Código UNSPSC:
12191502
NACRES:
NA.21
bp:
81-82 °C (lit.)

MXP 2,667.00


Check Cart for Availability

Solicitar un pedido a granel

Nombre del producto

Acetonitrilo, for UHPLC, suitable for mass spectrometry (MS)

grado

HPLC grade

Nivel de calidad

Agency

suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 8327
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019

cumplimiento norm.

suitable for FDA C-010.02

densidad de vapor

1.41 (vs air)

presión de vapor

72.8 mmHg ( 20 °C)

Ensayo

≥99.92%

Formulario

liquid

temp. de autoignición

973 °F

lim. expl.

16 %

técnicas

mass spectrometry (MS): suitable

índice de refracción

n20/D 1.344 (lit.)

bp

81-82 °C (lit.)

mp

−45 °C (lit.)

densidad

0.786 g/mL at 25 °C (lit.)

cadena SMILES

CC#N

aplicaciones

PFAS testing
food and beverages

Formato

neat

InChI

1S/C2H3N/c1-2-3/h1H3

Clave InChI

WEVYAHXRMPXWCK-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Acetonitrile, an aliphatic nitrile, is a highly volatile, aprotic polar organic solvent that finds wide use in analytical determinations. It is UV-transparent − a property that facilitates its utilization in spectrophotometric and fluorimetric analyses. Its low viscosity, high elution strength and miscibility in water makes it viable in many chromatography systems.
Its other applications include its use as a mobile phase additive and as an extraction solvent in liquid-liquid extraction (LLC), solid-phase extraction (SPE) and microextraction for chromatographic applications, etc.[1]

Aplicación

Acetonitrile may be used:
  • As an extraction solvent for the quantification of pesticide analytes in foodstuffs[2][3] and tea,[4] industrial dyes in juice and wine[5] by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).
  • As an organic modifier in the determination of bisphenol A-diglycidyl ether, bisphenol F-diglycidyl ether and their derivatives in canned food and beverages by fast LC–MS/MS.[6]

Acetonitrile, an organic solvent, is used as a mobile phase/extraction solvent in the ultra-high performance liquid chromatorgraphy − tandem mass spectrometry (UHPLC-MS) analysis of pesticides in tobacco samples.[7] It can be potentially used with a reverse-phase column to determine the concentration of diclofenac (DCF).[8]

Información legal

ASTM is a registered trademark of American Society for Testing and Materials

Pictogramas

FlameExclamation mark

Palabra de señalización

Danger

Clasificaciones de peligro

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

Código de clase de almacenamiento

3 - Flammable liquids

Clase de riesgo para el agua (WGK)

WGK 2

Punto de inflamabilidad (°F)

35.6 °F - closed cup

Punto de inflamabilidad (°C)

2.0 °C - closed cup


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Determination of 27 industrial dyes in juice and wine using ultra performance liquid chromatography with electrospray ionization tandem quadrupole mass spectrometry
Zhao S, et al.
Se Pu / Chinese Journal of Chromatography, 28(4), 356-362 (2010)
Barbara Giroud et al.
Journal of chromatography. A, 1316, 53-61 (2013-10-15)
Beebread is among the matrices suspected of contaminating honeybee. To better understand this contamination, the study aimed to develop an efficient, sensitive and reliable analytical method for the trace analysis of pesticides in beebread. This study focuses specifically on the
Rapid determination of organonitrogen, organophosphorus and carbamate pesticides in tea by ultrahigh-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS)
Zhao HX, et al.
Food Analytical Methods, 6(2), 497-505 (2013)
Gabrieli Bernardi et al.
Talanta, 161, 40-47 (2016-10-23)
An effective method has been developed and validated for the determination of residues of 55 pesticides in tobacco. The proposed sample preparation method is based on acetonitrile extraction, low-temperature precipitation (LTP) and dispersive solid phase extraction (d-SPE) clean-up. Gas chromatography
Acetonitrile, the polarity chameleon.
P K Zarzycki et al.
Analytical and bioanalytical chemistry, 397(3), 905-908 (2010-04-13)

Artículos

Learn about UHPLC-MS analysis of trastuzumab on a BIOshell™ 160A peptide C18 column and discover reduced solvent consumption in peptide mapping using 1.5 mm I.D. columns.

Chromolith® RP-18e columns optimize Oligo Standard 6 separation with varied flow rates and ion-pairing reagent evaluation.

LC-UV-MS workflow details teriparatide peptide mapping, including enzymatic digestion, separation conditions, and QTOF mass spectrometer identification.

Learn more about our Kava CRM solution for use in quantitative and qualitative analysis of kavalactones and flavokavains in kava products to confirm their potency and authenticity.

Protocolos

Chromatographic technique identifies insulin variants efficiently, aiding in pharmacokinetics.

Contenido relacionado

Las PFAS o «productos químicos eternos», persisten en el medio ambiente y pueden suponer un riesgo para la salud humana. Descubra nuestras herramientas de control medioambiental para cuantificación de las PFAS, para apoyar a los investigadores, reguladores y laboratorios en sus análisis de las PFAS.

FAS, or 'forever chemicals,' persist in the environment and pose risks to human health. Discover our environmental monitoring tools for PFAS quantification, aiding researchers, regulators, and labs in testing for PFAS.

Questions

1–2 of 2 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico