KGSKG3TTT1
Millipore Express® SHC, cápsula Opticap® XLT
Opticap® XLT 30, cartridge L 34.3 in. (87.2 cm), filter diam. 2.7 in. (6.9 cm)
Sinónimos:
Gamma Opticap® XLT HBP 30 Express SHC TC/TC
About This Item
Productos recomendados
Materiales
polyethersulfone filter (PES)
polyethylene support
polypropylene housing (PP)
silicon seal
Nivel de calidad
cumplimiento norm.
meets FDA CFR 210.3 (b) (6) (all component materials)
esterilidad
irradiated
non-sterile
Compatibilidad de esterilización
gamma compatible
Línea del producto
Opticap® XLT 30
Características
hydrophilic
Parámetros
1.0 bar max. inlet pressure (15 psi) at 80 °C
1000 mbar max. differential pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. inlet pressure (80 psi) at 25 °C
5500 mbar max. differential pressure (80 psi) at 25 °C
6.9 bar max. inlet pressure (100 psi) at 25 °C
76 L/min flow rate at 69 mbar (1 psi) and 23 °C
80 psig max. inlet pressure
técnicas
sterile filtration: suitable
Anchura
7.8 in.
Cartucho Al
34.3 in. (87.2 cm)
Tamaño de la unidad
30 in. (75 cm)
diám. del filtro
2.7 in. (6.9 cm)
filtración área
1.62 m2
impurezas
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
Matriz
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
punto de burbuja
≥4000 mbar (≥70 psig), air with water
Adaptador
1/4 in. fitting (vent/drain hose barb with double O-ring seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
¿Está buscando productos similares? Visita Guía de comparación de productos
Descripción general
Device Configuration: Capsule
Envase
Nota de preparación
3 autoclave cycles of 60 min @ 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
Nota de análisis
Otras notas
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer to wetting instructions of Filters with Millipore Express® Membrane use guide
- Storage Statement: Please refer to Filters with Millipore Express® Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Información legal
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico