Saltar al contenido
Merck

739553

Sigma-Aldrich

Poly(styrene-block-methyl methacrylate)

average Mn 32,000, block ratio of 2:1

Sinónimos:

PS-PMMA, block copolymer, Poly(b-methyl methacrylate-polystyrene), PS-block-PMMA, PS-PMMA

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Número de CAS:
Código UNSPSC:
12162002

Formulario

solid

mol peso

average Mn 10,000 (PMMA)
average Mn 22,000 (polystyrene)
average Mn 32,000

temperatura de transición

Tm 351-356 °C

Mw/Mn

<1.2

InChI

1S/C8H8.C5H8O2/c1-2-8-6-4-3-5-7-8;1-4(2)5(6)7-3/h2-7H,1H2;1H2,2-3H3

Clave InChI

ADFPJHOAARPYLP-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

22 kDa PS; 10 kDa PMMA; m ~200; n ~100

Pictogramas

Exclamation mark

Palabra de señalización

Warning

Frases de peligro

Consejos de prudencia

Clasificaciones de peligro

Eye Irrit. 2

Código de clase de almacenamiento

13 - Non Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

M H Geiger et al.
Clinical orthopaedics and related research, (382)(382), 258-266 (2001-01-12)
This controlled study compared the strength and porosity of 48 polymethylmethacrylate cement-implant constructs prepared with open bowl versus vacuum mix technique. Forty-eight blast finished stainless steel rods of 13 mm diameter were implanted with centralizers into 17-mm inner diameter tubes
Novel fabrication of 2D and 3D inverted opals and their application.
Jae Ah Lee et al.
Small (Weinheim an der Bergstrasse, Germany), 7(18), 2581-2586 (2011-08-03)
F N K Kwong et al.
The Journal of bone and joint surgery. British volume, 88(1), 120-122 (2005-12-21)
The outcome of a cemented hip arthroplasty is partly dependent on the type of cement which is used. The production of an interface gap between the stem and the cement mantle as a result of shrinkage of the cement, may
S J Breusch et al.
Acta orthopaedica Scandinavica, 72(1), 29-35 (2001-05-01)
In a cadaver study, we prepared 29 paired human cadaver femora using 3 different broaches of identical geometry but different surface characteristics. In one group of 20 pairs, preparation with chipped-toothed broaches was compared to diamond-shaped broaches; in the other
MN: Surgical LPN files product liability suit: cement Mfgr.'s failure to warn of health hazard.
Nursing law's Regan report, 42(8), 3-3 (2004-08-11)

Questions

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico