推荐产品
等級
certified reference material
TraceCERT®
agency
EPA 8081
產品線
TraceCERT®
CofA
current certificate can be downloaded
特點
standard type calibration
包裝
ampule of 1 mL
濃度
1000 μg/mL in isooctane
技術
HPLC: suitable
gas chromatography (GC): suitable
應用
agriculture
cleaning products
cosmetics
environmental
food and beverages
personal care
格式
single component solution
儲存溫度
2-30°C
InChI
1S/C10H8Cl8/c1-4-7(2-11,3-12)9(16)6(14)5(13)8(4,15)10(9,17)18/h5-6H,1-3H2
InChI 密鑰
OEJNXTAZZBRGDN-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
應用
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
其他說明
This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.
法律資訊
TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany
訊號詞
Danger
危險分類
Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3
標靶器官
Central nervous system
儲存類別代碼
3 - Flammable liquids
水污染物質分類(WGK)
WGK 3
閃點(°F)
10.4 °F - closed cup
閃點(°C)
-12 °C - closed cup
Se pu = Chinese journal of chromatography, 30(1), 14-20 (2012-06-07)
A novel method for the determination of representative toxaphene congeners in traditional Chinese herbal medicines was developed. Ginseng and Milkvetch Root were selected as the samples and seven toxaphene congeners were selected as the monitoring objects. The samples were extracted
Chemosphere, 82(1), 32-36 (2010-11-13)
For decades, toxaphene had been used as a major chloropesticide. Degradation of the multicomponent mixture in the environment was mainly reported to be due to anaerobic dechlorination and hydrodechlorination. Little was known about oxidative transformation processes and the potential hydroxylated
Comparative biochemistry and physiology. Toxicology & pharmacology : CBP, 156(1), 37-41 (2012-04-14)
We evaluated toxaphene-induced acute toxicity in Hydra magnipapillata. The median lethal concentrations of the animals (LC(50)) were determined to be 34.5 mg/L, 25.0 mg/L and 12.0 mg/L after exposure to toxaphene for 24 h, 48 h and 72 h, respectively.
Integrated environmental assessment and management, 8(3), 523-529 (2011-12-14)
A revised risk assessment for toxaphene was developed, based on the assumption that fish consumers are only exposed to toxaphene residues that differ substantially from technical toxaphene due to environmental degradation and metabolism. In vitro studies confirmed that both technical
Journal of chromatography. A, 1270, 262-268 (2012-11-20)
Determinative methods based on gas chromatography-negative chemical ionization mass spectrometry (GC-NCI/MS) provide improved sensitivity and specificity for toxaphene in environmental samples, but are subject to misidentification due to oxygen reaction in the presence of polychlorinated biphenyls (PCBs). The goal of