推荐产品
等级
certified reference material
TraceCERT®
质量水平
产品线
TraceCERT®
保质期
limited shelf life, expiry date on the label
制造商/商品名称
Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
储存温度
−20°C
SMILES字符串
CCC\C(=N/OCC)C1=C(O)CC(CC(C)SCC)CC1=O
InChI
1S/C17H29NO3S/c1-5-8-14(18-21-6-2)17-15(19)10-13(11-16(17)20)9-12(4)22-7-3/h12-13,19H,5-11H2,1-4H3/b18-14+
InChI key
CSPPKDPQLUUTND-NBVRZTHBSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma aldrich.com
Sethoxydim is a selective, systemic, and cyclohexanedione oxime herbicide, absorbed mainly by foliage, and, to a lesser extent, by roots. It is an acetyl CoA carboxylase (ACCase) inhibitor, which inhibits the incorporation of acetate into fatty acids and interferes with the formation of phospholipids used in building new membranes. It is used to control annual and perennial grass weeds (except Poa spp.) in broad-leaved crops, including cotton, oilseed rape, soybeans, sugar beets, fodder beets, sunflowers, spinach, potatoes, tobacco, peanuts, strawberries, alfalfa, flax, and vegetables.
Sethoxydim is not approved for use in the European Union (EU) as a plant protection agent, following Regulation (EC) No. 1107/2009 and repealing Directive 91/414/EEC. But maximum residue levels of 0.05 mg/kg to 10 mg/kg are allowed for the presence of sethoxydim, expressed as a sum of sethoxydim and clethodim including their degradation products, in products of plant and animal origin, according to the EU Reg. No 839/2008.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma aldrich.com
Sethoxydim is a selective, systemic, and cyclohexanedione oxime herbicide, absorbed mainly by foliage, and, to a lesser extent, by roots. It is an acetyl CoA carboxylase (ACCase) inhibitor, which inhibits the incorporation of acetate into fatty acids and interferes with the formation of phospholipids used in building new membranes. It is used to control annual and perennial grass weeds (except Poa spp.) in broad-leaved crops, including cotton, oilseed rape, soybeans, sugar beets, fodder beets, sunflowers, spinach, potatoes, tobacco, peanuts, strawberries, alfalfa, flax, and vegetables.
Sethoxydim is not approved for use in the European Union (EU) as a plant protection agent, following Regulation (EC) No. 1107/2009 and repealing Directive 91/414/EEC. But maximum residue levels of 0.05 mg/kg to 10 mg/kg are allowed for the presence of sethoxydim, expressed as a sum of sethoxydim and clethodim including their degradation products, in products of plant and animal origin, according to the EU Reg. No 839/2008.
应用
The certified reference material (CRM) is intended to be used as a calibrant for chromatography and other analytical techniques.
Sethoxydim CRM may also be used as given below:
Sethoxydim CRM may also be used as given below:
- Simultaneous residue analysis of 379 pesticides in human serum samples using the QuEChERS extraction method and liquid chromatography-tandem mass spectrometry (LC-MS/MS)
- Method development for multi-residue analysis of pesticides in agricultural water samples, extracted by QuEChERS method using liquid chromatography (LC) with mass spectrometry (MS)
- Determination of 260 pesticide residues in human urine samples using a scaled-down QuEChERS approach for sample extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS)
- Evaluation of liquid chromatography high-resolution mass spectrometry (UHPLC-HRMS) using time-of-flight mass spectrometry as an accurate-mass multi-residue screening method to estimate multi-class organic contaminants in baby food samples
- Development of a semi-automated method for the analysis of 261 pesticides and 41 environmental contaminants in catfish muscle samples by QuEChERS sample extraction and low pressure-GC-MS/MS and UHPLC-MS/MS, following an automated robotic micro-SPE clean-up
- Multi-residue analysis of 200 pesticides and 65 environmental contaminants in 10 samples of cattle, swine, and chicken muscles by fast low-pressure gas chromatography (LP-GC-MS/MS) and ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS)
法律信息
TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany
危险声明
预防措施声明
危险分类
Aquatic Chronic 2
储存分类代码
10 - Combustible liquids
WGK
WGK 2
闪点(°F)
Not applicable
闪点(°C)
Not applicable
Development and application of a multi-residue method to determine pesticides in agricultural water using quechers extraction and lc-ms/ms analysis
Song NH, et al.
Separations, 7(4), 52-52 (2020)
Yongho Shin et al.
Journal of agricultural and food chemistry, 66(13), 3550-3560 (2018-03-15)
A screening method for simultaneous analysis of 379 pesticides in human serum was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Electrospray ionization with positive/negative switching mode of LC-MS/MS was adopted, and scheduled multiple reaction monitoring for each target compound was
Lijun Han et al.
Food chemistry, 319, 126592-126592 (2020-03-21)
A fast, fit-for-purpose, high-throughput method was developed and validated for the analysis of 302 targeted contaminants in catfish muscle. Targeted contaminants included pesticides and metabolites with US regulatory levels, plus other lipophilic pesticides and environmental contaminants: PAHs, PCBs, PBDEs and
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门