跳转至内容
Merck

N-017

Supelco

去甲哌替啶标准液 溶液

100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C14H19NO2
CAS号:
分子量:
233.31
EC號碼:
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

certified reference material

形狀

liquid

特點

Snap-N-Spike®/Snap-N-Shoot®

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

drug control

Narcotic Licence Schedule A (Switzerland); estupefaciente (Spain); Decreto Lei 15/93: Tabela IA (Portugal)

濃度

100 μg/mL in methanol

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

forensics and toxicology

格式

single component solution

儲存溫度

−20°C

SMILES 字串

O=C(OCC)C1(C2=CC=CC=C2)CCNCC1

InChI

1S/C14H19NO2/c1-2-17-13(16)14(8-10-15-11-9-14)12-6-4-3-5-7-12/h3-7,15H,2,8-11H2,1H3

InChI 密鑰

QKHMFBKXTNQCTM-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般說明

去甲哌替啶是阿片类镇痛药哌替啶的主要有毒代谢物。 该认证Snap-N-Spike®溶液适用于通过LC-MS/MS、LC/MS 或 GC/MS法进行止痛药处方监测、临床毒理学、尿液药物测试或法医分析。哌替啶是一种具有类似吗啡作用的合成阿片类药物,可用作止痛药。

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes,Central nervous system

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

49.5 °F - closed cup

閃點(°C)

9.7 °C - closed cup


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

J L Plummer et al.
Toxicology, 95(1-3), 37-44 (1995-01-06)
This study investigated behavioural effects of the toxic pethidine metabolite, norpethidine, in rats and its interactions with reserpine, apomorphine and physostigmine. Following intraperitoneal administration, brain concentrations of norpethidine reached a plateau after 20-40 min and remained elevated for 2 h.
Meperidine in patient-controlled analgesia: a near-fatal mishap.
R J Geller
Anesthesia and analgesia, 76(3), 655-657 (1993-03-01)
Thomas T Simopoulos et al.
Archives of surgery (Chicago, Ill. : 1960), 137(1), 84-88 (2002-01-31)
Intravenous patient-controlled analgesia (IV PCA) meperidine hydrochloride can be used with a reasonable margin of safety. A retrospective review was performed of 355 medical records of patients receiving IV PCA meperidine treatment. Four groups of patients were defined, based on
J H Vranken et al.
Acta anaesthesiologica Scandinavica, 49(5), 665-670 (2005-04-20)
Intrathecal administration of meperidine, an opioid with local anesthetic activity, can induce analgesia in patients with intractable cancer pain. However, continuous intrathecal administration may result in the accumulation of normeperidine, responsible for central nervous system toxicity. Ten patients with neuropathic
W D Ngan Kee et al.
Anaesthesia and intensive care, 24(1), 51-55 (1996-02-01)
We evaluated a disposable device (Baxter PCA Infusor) for patient-controlled epidural analgesia (PCEA) using pethidine in twenty women after lower segment caesarean section. Efficacy, as measured by visual analogue pain scores, was comparable with historical controls from PCEA studies using

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门