推荐产品
化驗
99.999% trace metals basis
形狀
solid
雜質
≤15.0 ppm Trace Metal Analysis
mp
626 °C (lit.)
密度
4.51 g/mL at 25 °C (lit.)
SMILES 字串
[I-].[Cs+]
InChI
1S/Cs.HI/h;1H/q+1;/p-1
InChI 密鑰
XQPRBTXUXXVTKB-UHFFFAOYSA-M
正在寻找类似产品? 访问 产品对比指南
應用
碘化铯可以作为 前体合成无铅钙钛矿材料 Cs2NaBiI6(CNBI)。CNBI 具有高度 稳定性,可应用于太阳能电池、LED 和它还发现在预防体内钙消耗中的应用。 激光器领域。
它可用于制备适用于高分辨率伽马光谱的最亮红色发射 Cs2HfI6 闪烁体 。
它还可以用于合成铯基纳米晶体,用于检测电离辐射。
它可用于制备适用于高分辨率伽马光谱的最亮红色发射 Cs2HfI6 闪烁体 。
它还可以用于合成铯基纳米晶体,用于检测电离辐射。
特點和優勢
- 高量子效率
- 对周围空气和气体环境具有高稳定性
常用于医疗成像荧光屏、闪烁体、热量计和各种粒子探测器等设备。
訊號詞
Warning
危險聲明
危險分類
Aquatic Acute 1 - Repr. 2
儲存類別代碼
13 - Non Combustible Solids
水污染物質分類(WGK)
WGK 2
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
dust mask type N95 (US), Eyeshields, Faceshields, Gloves
其他客户在看
Journal of magnetic resonance (San Diego, Calif. : 1997), 212(2), 460-463 (2011-09-13)
The accurate temperature measurement of solid samples under magic-angle spinning (MAS) is difficult in the cryogenic regime. It has been demonstrated by Thurber et al. (J. Magn. Reson., 196 (2009) 84-87) [10] that the temperature dependent spin-lattice relaxation time constant
Optics express, 17(23), 20684-20693 (2009-12-10)
We present a versatile terahertz time-domain spectrometer which allows reflection measurements at normal incidence and double pass transmission measurements in a single experimental setup. Two different modes for transmission measurements are demonstrated for precise measurements of transparent high or low
Physics in medicine and biology, 54(9), 2845-2861 (2009-04-23)
This paper presents detective quantum efficiency (DQE) data measured for a range of x-ray beam qualities for two full-field digital mammography (FFDM) systems: a caesium iodide (CsI) detector-based unit and a system designed around an amorphous selenium (a-Se) x-ray detector.
Medical physics, 35(7), 3180-3193 (2008-08-14)
The practice of diagnostic x-ray imaging has been transformed with the emergence of digital detector technology. Although digital systems offer many practical advantages over conventional film-based systems, their spatial resolution performance can be a limitation. The authors present a Monte
IEEE transactions on medical imaging, 28(5), 696-702 (2009-03-11)
We quantify the variation in resolution due to anisotropy caused by oblique X-ray incidence in indirect flat-panel detectors for computed tomography breast imaging systems. We consider a geometry and detector type utilized in breast computed tomography (CT) systems currently being
商品
Colloidal quantum dots (CQDs) are semiconducting crystals of only a few nanometers (ca. 2–12 nm) coated with ligand/surfactant molecules to help prevent agglomeration.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门