Accéder au contenu
Merck
Toutes les photos(1)

Principaux documents

217506

Supelco

AmberChrom 50WX8 Ion Exchange Resin

hydrogen form, 100-200 mesh

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
(C10H12 · C10H10 · C8H8)x
Numéro CAS:
Numéro MDL:
Code UNSPSC :
23151817
Nomenclature NACRES :
SB.52
Le tarif et la disponibilité ne sont pas disponibles actuellement.

Nom du produit

Amberchrom 50WX8 hydrogen form, hydrogen form, 100-200 mesh

Description

cross-linkage 8%

Niveau de qualité

Forme

beads

Humidité

50-58%

Technique(s)

LPLC: suitable

Matrice

styrene-divinylbenzene (gel)

Groupe de la matrice active

sulfonic acid functional group

Taille des particules

100-200 mesh

Capacité

1.7 meq/mL by wetted bed volume

Technique de séparation

cation exchange

Chaîne SMILES 

C(C)c3c(cccc3)C=C.c2(c(cccc2)C=C)C=C.c1(ccccc1)C=C

InChI

1S/C10H12.C10H10.C8H8/c2*1-3-9-7-5-6-8-10(9)4-2;1-2-8-6-4-3-5-7-8/h3,5-8H,1,4H2,2H3;3-8H,1-2H2;2-7H,1H2

Clé InChI

NWUYHJFMYQTDRP-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

La résine Amberlite HPR4800 Cl sous forme hydrogénée sert de résine de nettoyage et peut être régénérée avec de l′acide sulfurique 0,25 N lorsqu′elle perd de son efficacité.[1] L′Amberlite HPR4800 Cl sous forme hydrogénée est utilisée comme catalyseur.[2] Elle est employée dans les échantillons à fraction surnageante dé-ionisante pour la chromatographie sur papier.[3]

Application

La résine Amberlite HPR4800 Cl sous forme hydrogénée peut être utilisée dans les milieux de séparation pour CCM (TLC), chromatographie sur papier et LPLC.
Résine échangeuse de cations fortement acide pour les séparations fines en chimie et pharmacie;répond aux exigences de la réglementation FDA 21 CFR 173.25.

Autres remarques

Cett résine n′a pas été spécialement préparée ni purifiée. Nous suggérons de lui appliquer une élution et un lavage préliminaires appropriés.

Informations légales

Amberchrom is a trademark of DuPont de Nemours, Inc.
Amberlite is a trademark of DuPont de Nemours, Inc.

Pictogrammes

Exclamation mark

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Eye Irrit. 2

Code de la classe de stockage

13 - Non Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

dust mask type N95 (US), Eyeshields, Gloves


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Chemical composition and ultrastructure of wild-type and white mutantAspergillus nidulans conidial walls.
Claverie-Martin, Felix, Maria R. Diaz-Torres, and Michael J. Geoghegan.
Current Microbiology, 16, 281-287 (1988)
Novel ion exchange chromatographic method using conductimetric detection.
Small, Hamish, Timothy S. Stevens, and William C. Bauman.
Analytical Chemistry, 47, 1801-1809 (1975)
Hydrogen generation from hydrolysis of sodium borohydride using Ni-Ru nanocomposite as catalysts.
Liu, Cheng-Hong, et al.
International Journal of Hydrogen Energy, 34, 2153-2163 (2009)

Questions

1–7 of 7 Questions  
  1. How can a Dowex 1x4 resin in the chloride form be converted to the acidic form?

    1 answer
    1. This product is a strongly acidic cation exchange resin in the H+ form. There is no way to convert between this and being in the chloride form, which would constitute an anion exchange resin. A resin cannot be converted from an anion exchange resin to a cation exchange resin, or vice versa. A resin in the H+ form can, however, be converted to the sodium form by flushing with two volumes of 1 N NaOH, whereby the sodium ions take the place of the hydrogen.

      Helpful?

  2. What is the meaning of 1.7 meq/mL by wetted bed volume for this resin? Do we have to consider the molecular mass of resin or the reaction mixture that we are going to purify?

    1 answer
    1. A milliequivalent is one-thousandth of an equivalent. The unit mEq is related to the number (mmol) and electrical charge of ions in solution. 1.7 mEq/mL means 1.7 millimoles of charge per milliliter of resin bed.

      Yes, you will need to consider the milliequivalents of charge on the resin and the millimoles of the material that you are trying to purify; make sure that the first is greater.

      Helpful?

  3. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  4. How do I prepare Product 217506, Dowex® 50WX8 - hydrogen form, 100-200 mesh resin, for use?

    1 answer
    1. Cation exchange resins can be prepared by initially swirling with deionized water in a flask (no stir bars, please), allowing them to settle for 15-20 minutes, and decanting the fines.  To fully activate the resin, repeat the procedure 2-3 times with 2N hydrochloric or sulfuric acid, and rinse with copious amounts of water until >pH 5; this procedure may be completed with use of a Büchner funnel.

      Helpful?

  5. Is Product 217506, Dowex® 50WX8 - hydrogen form, 100-200 mesh resin, the same as AG50W-X8?

    1 answer
    1. The AG® designation indicates that a resin has been specially cleaned and certified for analytical use.  In most cases, resin that you prepare yourself will be suitable for your application.   (® Bio-Rad Laboratories, Hercules,CA)

      Helpful?

  6. What is the particle size of Product 217506, Dowex® 50WX8 - hydrogen form, 100-200 mesh resin?

    1 answer
    1. This is Dowex 50Wx8 100-200 mesh, with beads measuring 75-150 microns.  This particle size is consistent in water, but the resin will shrink when exchanged to other cationic forms, and it will swell when exposed to organic solvents. You may test the swelling characteristics of a resin to be used in your application by doing the initial solvent exchanges in a graduated cylinder.

      Helpful?

  7. How can I convert a cation exchange resin from the hydrogen form to the sodium form?

    1 answer
    1. To convert a cation exhcange resin from the hydrogen form to the sodium form, use two to four bed volumes of 0.5-2.0% NaCl or NaOH.

      Helpful?

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique