material
PE frit (20 μm)
polypropylene
Quality Level
feature
endcapped
composition
bed wt., 500 mg
packaging
pk of 30
technique(s)
solid phase extraction (SPE): suitable
surface area
480 m2/g
volume
6 mL
matrix
silica gel base material (irregularly shaped, acid washed)
matrix active group
amino phase
Looking for similar products? Visit Product Comparison Guide
1 of 4
This Item | 52636-U | 52637-U | 52640-U |
---|---|---|---|
silica gel base material (irregularly shaped, acid washed) | silica gel base material (irregularly shaped, acid washed) | silica gel base material (irregularly shaped, acid washed) | silica gel base material (irregularly shaped, acid washed) |
amino phase | amino phase | amino phase | amino phase |
50 μm | 50 μm | 50 μm | 50 μm |
70 Å pore size | 70 Å pore size | 70 Å pore size | 70 Å pore size |
6 mL | 1 mL | 3 mL | 6 mL |
General description
Sample Matrix Compatibility: Organic or aqueous solutions
- Polymerically bonded, aminopropyl phase that is very polar in nature (hydrogen bonding) allowing for both normal phase and ion exchange applications
- A weak anion exchanger with a pKa of 9.8. At pH 7.8 or below, the functional groups are positively charged
- Ion exchange capacity is ∼ 0.43 meq/g.
- Allows the rapid release of very strong anions such as sulfonic acids that may be retained irreversibly by strong anion exchangers
- Can be used in some reversed-phase applications (due to ethyl spacer); however, it is predominately used as an ion-exchange or normal phase sorbent due to its polar nature
Legal Information
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point(F)
>464.0 °F
Flash Point(C)
> 240 °C
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
SPE retention mechanism in this case is based on the electrostatic attraction of charged functional groups of the analyte(s) to oppositely charged functional groups on the sorbent.
Protocols
Normal-phase SPE separates analytes based on polar interaction with sorbents in diverse sample matrices.
Normal-phase SPE separates analytes based on polar interaction with sorbents in diverse sample matrices.
Normal-phase SPE separates analytes based on polar interaction with sorbents in diverse sample matrices.
Normal-phase SPE separates analytes based on polar interaction with sorbents in diverse sample matrices.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service