48541

Supelco

Trichlorofluoromethane

analytical standard

Synonyme(s) :

CFC-11, Freon® 11

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
Cl3CF
Numéro CAS:
Poids moléculaire :
137.37
Numéro Beilstein :
1732469
Numéro CE :
Numéro MDL:
Code UNSPSC :
12000000
ID de substance PubChem :

Qualité

analytical standard

Niveau de qualité

Densité de vapeur

5.04 (vs air)

Pression de vapeur

12.85 psi ( 20 °C)
39.17 psi ( 55 °C)

CofA (certificat d'analyse)

current certificate can be downloaded

Conditionnement

ampule of 5000 mg

Technique(s)

HPLC: suitable
gas chromatography (GC): suitable

Indice de réfraction

n20/D 1.3821 (lit.)

Point d'ébullition

23.7 °C (lit.)

Pf

−111-−110 °C (lit.)

Densité

1.494 g/mL at 25 °C (lit.)

Application(s)

cleaning products
cosmetics
environmental
food and beverages
personal care

Format

neat

Température de stockage

2-8°C

Chaîne SMILES 

FC(Cl)(Cl)Cl

InChI

1S/CCl3F/c2-1(3,4)5

Clé InChI

CYRMSUTZVYGINF-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Informations légales

Freon is a registered trademark of E. I. du Pont de Nemours and Company

Pictogrammes

Exclamation mark

Mention d'avertissement

Warning

Mentions de danger

Conseils de prudence

Classification des risques

Ozone 1

Code de la classe de stockage

10 - Combustible liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

Eyeshields, Faceshields, Gloves


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

P Sharma et al.
Rapid communications in mass spectrometry : RCM, 18(20), 2383-2387 (2004-09-24)
Nonresonant laser-induced multiphoton dissociation/ionization studies have been conducted for trichloromethane (CHCl3) and trichlorofluoromethane (CFCl3) at 355 nm, using time-of-flight mass spectrometry (TOFMS). The molecular ion signal was found to be missing for both these compounds, and very similar fragmentation patterns
A Groppi et al.
Journal of forensic sciences, 39(3), 871-876 (1994-05-01)
A case of lethal poisoning due to trichlorofluoromethane (FC11) inhalation is described. The fluorocarbon was determined in biological tissues by headspace gas chromatography-mass spectrometry. FC11 was detected in all the examined tissues, with decreasing levels in heart, lung, brain, liver
Konrad Stemmler et al.
Environmental science & technology, 41(4), 1145-1151 (2007-06-28)
HFC-365mfc (1,1,1,3,3-pentafluorobutane) is an industrial chemical used for polyurethane foam blowing. From early 2003, HFC-365mfc has been commercially produced as a substitute for HCFC-141b, whose use in Europe has been banned since January 2004. We describe the first detection of
Kai Sheng Diao et al.
Bulletin of environmental contamination and toxicology, 84(2), 170-174 (2009-11-28)
Ab initio calculations have been performed on complexes of CFCl3 with SO2. Ten complexes were found stable, the interaction energies that reflect their stability were corrected by the basis set superposition error and the correction of zero-point energy. The natures
A Vinegar
Toxicological sciences : an official journal of the Society of Toxicology, 60(1), 20-27 (2001-02-27)
Human exposure guidelines for halogenated hydrocarbons (halons) and halon replacement chemicals have been established using dose-response data obtained from canine cardiac sensitization studies. In order to provide a tool for decision makers and regulators tasked with setting guidelines for egress

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique