Accéder au contenu
Merck
Toutes les photos(2)

Key Documents

KCQS07

Sigma-Aldrich

KiCqStart® One-Step Probe RT-qPCR ReadyMix

for Bio-Rad, Cepheid, Eppendorf, Illumina, Corbett, and Roche systems

Synonyme(s) :

KiCqStart® One Step Probe RT-qPCR Readymix

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41106300
Nomenclature NACRES :
NA.55

Forme

liquid

Utilisation

sufficient for 500 reactions

Caractéristiques

dNTPs included
hotstart

Conditions de stockage

protect from light

Technique(s)

qPCR: suitable

Couleur

light blue

Entrée

purified RNA

Compatibilité

Bio-Rad CFX384
Bio-Rad CFX96
Bio-Rad MJ Chromo4
Bio-Rad MJ Opticon 2
Bio-Rad MJ Opticon
Bio-Rad MiniOpticon
Eppendorf® Mastercycler ep realplex2 s
Eppendorf® Mastercycler ep realplex
Illumina Eco qPCR
Qiagen Corbett Rotor-Gene 3000
Qiagen Corbett Rotor-Gene 6000
Qiagen Corbett Rotor-Gene Q
Roche LightCycler 480

Méthode de détection

probe-based

Conditions d'expédition

dry ice

Température de stockage

−20°C

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

KiCqStart® One-Step Probe RT-qPCR ReadyMix is a ready-to-use, highly sensitive master mix for reverse transcription quantitative PCR (RT-qPCR) of RNA templates using hybridization probe detection chemistries such as TaqMan® 5′-hydrolysis probes on real-time PCR systems (refer to instrument compatibility section to select the appropriate reagent for your machine). First-strand cDNA synthesis and PCR amplification are carried out in the same tube without opening between procedures. It is ideal for highly sensitive quantification of RNA viruses or low abundance RNA targets as well as high throughput gene-expression studies. The system has been optimized to deliver maximum RT-PCR efficiency, sensitivity, and specificity in reduced reaction volumes and fast cycle times.

KiCqStart® One-Step Probe RT-qPCR ReadyMix contains all required components for RT-qPCR except RNA template and probe. It is compatible with all dual-labeled probe chemistries. The reverse transcriptase is an engineered M-MLV with reduced RNase H activity and improved activity and stability at higher temperatures. The use of higher temperatures (50 to 55°C) for the first-strand step of one-step RT-qPCR provides higher specificity for primer annealing and disruption of RNA secondary structure that can interfere with cDNA synthesis.

KiCqStart® One-Step Probe RT-qPCR ReadyMix is highly resistant to PCR inhibitors. A key component of the ReadyMix is an ultra-pure, highly processive, thermostable DNA polymerase that is combined with high avidity monoclonal antibodies. This provides an extremely stringent automatic hot-start that minimizes the potential for primer-dimer and other non-specific PCR artifacts. The light blue color of the inert dye simplifies reaction assembly in white, or clear, plates and helps to minimize pipetting or mixing errors. The dye does not interfere with qPCR performance or affect the stability of the product.

Application

KiCqStart® One-Step Probe RT-qPCR ReadyMix has been used:
  • in quantitative real-time polymerase chain reaction (qRT-PCR) for gene expression studies
  • in cell type-specific transcript analysis for determining the cycle threshold (Ct) value
  • for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA detection from nasopharyngealand oropharyngeal swabs
  • for amplification of reverse-transcribed cDNA

Caractéristiques et avantages

  • Assay results in as little as 33 minutes
  • Highly efficient and sensitive real-time PCR results
  • Little/no optimization required

Composants

2X reaction buffer containing dATP, dCTP, dGTP, dTTP, magnesium chloride, reverse transcriptase, RNase inhibitor protein, hot-start DNA polymerase, inert blue qPCR dye, and stabilizers

packaging:
500 reactions* = 5 X 1 mL tubes
*number of reactions based on a 20uL volume

Autres remarques

Different real-time PCR systems employ different strategies for normalization of fluorescent signals and correction of well-to-well optical variations. It is critical to match the appropriate qPCR reagent to your specific instrument.KiCqStart® One-Step Probe RT-qPCR ReadyMix does not contain an internal reference dye. Compatible instruments include:
  • Bio-Rad® CFX384
  • Bio-Rad CFX96
  • Bio-Rad MiniOpticon
  • Bio-Rad/MJ Chromo4
  • Bio-Rad/MJ Opticon 2
  • Bio-Rad/MJ Opticon
  • Cepheid SmartCycler®
  • Eppendorf Mastercycler® ep realplex
  • Eppendorf Mastercycler ep realplex2 s
  • Illumina Eco qPCR
  • Qiagen/Corbett Rotor-Gene® 3000
  • Qiagen/Corbett Rotor-Gene 6000• Qiagen/Corbett Rotor-Gene Q
  • Roche LightCycler® 480

Informations légales

Bio-Rad is a registered trademark of Bio-Rad Laboratories, Inc.
CFX384 is a trademark of Bio-Rad Laboratories, Inc.
CFX96 is a trademark of Bio-Rad Laboratories, Inc.
Chromo4 is a trademark of Bio-Rad Laboratories, Inc.
Eppendorf is a registered trademark of Eppendorf AG
KiCqStart is a registered trademark of QIAGEN Beverly Inc.
LightCycler is a registered trademark of Roche
Mastercycler is a registered trademark of Eppendorf AG
MiniOpticon is a trademark of Bio-Rad Laboratories, Inc.
Opticon is a trademark of Bio-Rad Laboratories, Inc.
ReadyMix is a trademark of Sigma-Aldrich Co. LLC
Rotor-Gene is a registered trademark of Qiagen GmbH
SmartCycler is a registered trademark of Cepheid, Inc.
TaqMan is a registered trademark of Roche Molecular Systems, Inc.

Code de la classe de stockage

12 - Non Combustible Liquids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Insulin-resistant subjects have normal angiogenic response to aerobic exercise training in skeletal muscle, but not in adipose tissue
Walton R G, et al.
Physiological Reports, 3(6), 145-153 (2015)
América Vanoye-Carlo et al.
Brain research, 1715, 73-83 (2019-03-25)
The function of synaptic vesicle protein 2A (SV2A) has not been clearly identified, although it has an essential role in normal neurotransmission. Changes in SV2A expression have been linked to several diseases that could implicate an imbalance between excitation and
Maiken W Rosenstierne et al.
Scientific reports, 11(1), 22214-22214 (2021-11-17)
Rapid nucleic-acid based tests that can be performed by non-professionals outside laboratory settings could help the containment of the pandemic SARS-CoV-2 virus and may potentially prevent further widespread lockdowns. Here, we present a novel compact portable detection instrument (the Egoo
Fabio Sossai Possebon et al.
Journal of virological methods, 300, 114414-114414 (2021-12-14)
COVID-19 has posed a worldwide public health challenge affecting millions of people in different countries. Rapid and efficient detection of SARS-CoV-2 is essential for pandemic control. Reverse Transcription quantitative PCR (RT-qPCR) of nasopharyngeal swabs is the gold standard method for
Bhasker Dharavath et al.
Heliyon, 6(7), e04405-e04405 (2020-07-16)
Early diagnosis of SARS-CoV-2 infected patients is essential to control the dynamics of the COVID-19 pandemic. We develop a rapid and accurate one-step multiplex TaqMan probe-based real-time RT-PCR assay, along with a computational tool to systematically analyse the data. Our

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique