GE17-6003-19
DeStreak™ Rehydration Solution
Cytiva 17-6003-19, pkg of 5 × 3 mL
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Forme
liquid
Caractéristiques
wetted part: no
Conditionnement
pkg of 5 × 3 mL
Fabricant/nom de marque
Cytiva 17-6003-19
Conditions de stockage
(Rehydration Solution -20 °C Reagent 2 - 8 °C)
Couleur
Colorless
Conditions d'expédition
dry ice
Température de stockage
−20°C
Catégories apparentées
Description générale
DeStreak™ Rehydration Solution.
Application
The appearance of streaks that distort 2-D electrophoresis maps is a common problem, occurring most frequently when running gels that contain regions greater than pH 7.0. Increased sample load, increased length of the IPG strip, or using a narrower pH gradient worsen the problem. Extra spots on 2-D gels, caused by nonspecific oxidation of Proteins, is another difficulty encountered when running gels containing basic regions. Both streaking and nonspecific oxidation result in poorly resolved Protein patterns and reduced reproducibility between electrophoresis runs.
DeStreak™ Rehydration Solution effectively eliminates nonspecific oxidation by maintaining Protein thiol groups in a single oxidation state, irrespective of sample load, pH range, or run length. Protein patterns are stabilized in IPG strips of any length and pH gradient ensuring the same stable and reproducible pattern in every analysis. The effectiveness of DeStreak™ Rehydration Solution is maintained at the high sample loads and long run times required for preparative gel electrophoresis.
DeStreak™ Rehydration Solution contains optimized concentrations of urea, thiourea, CHAPS, and DeStreak™ Reagent. The solution is ready for use after addition of the appropriate IPG buffer. DeStreak™ Reagent is also available separately in a 1-ml pack size.
DeStreak™ Rehydration Solution effectively eliminates nonspecific oxidation by maintaining Protein thiol groups in a single oxidation state, irrespective of sample load, pH range, or run length. Protein patterns are stabilized in IPG strips of any length and pH gradient ensuring the same stable and reproducible pattern in every analysis. The effectiveness of DeStreak™ Rehydration Solution is maintained at the high sample loads and long run times required for preparative gel electrophoresis.
DeStreak™ Rehydration Solution contains optimized concentrations of urea, thiourea, CHAPS, and DeStreak™ Reagent. The solution is ready for use after addition of the appropriate IPG buffer. DeStreak™ Reagent is also available separately in a 1-ml pack size.
Caractéristiques et avantages
- Improves reproducibility and quality of 2-D gels by preventing streaking.
- Eliminates extra spots caused by nonspecific oxidation of Proteins.
- Stabilizes Proteins throughout entire 2-D runs, ensuring simplified, well-resolved Protein patterns.
- Highly suitable for both analytical and preparative gels.
Stockage et stabilité
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Remarque sur l'analyse
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
Informations légales
DeStreak is a trademark of Cytiva
Mention d'avertissement
Warning
Mentions de danger
Conseils de prudence
Code de la classe de stockage
12 - Non Combustible Liquids
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique