Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

1.03701

Supelco

Hexane

≥99% (GC), suitable for LC/MS, LiChrosolv®

Synonyme(s) :

n-Hexane

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
CH3(CH2)4CH3
Numéro CAS:
Poids moléculaire :
86.18
Numéro Beilstein :
1730733
Numéro MDL:
Code UNSPSC :
41116105
Numéro de classement CE :
203-777-6
Nomenclature NACRES :
NA.03

product name

Hexane, hypergrade for LC-MS LiChrosolv®

Densité de vapeur

~3 (vs air)

Niveau de qualité

Pression de vapeur

256 mmHg ( 37.7 °C)
5.2 psi ( 37.7 °C)
~132 mmHg ( 20 °C)

Gamme de produits

LiChrosolv®

Pureté

≥99% (GC)

Forme

liquid

Température d'inflammation spontanée

453 °F

Limite d'explosivité

7.7 %

Technique(s)

LC/MS: suitable

Impuretés

≤0.0002 meq/g Acidity
≤0.0002 meq/g Alkalinity
≤0.005% Water
≤10 ppb Al (Aluminium)
≤10 ppb Ca (Calcium)
≤10 ppb Fe (Iron)
≤10 ppb Mg (Magnesium)
≤10 ppb Na (Sodium)
≤5 ppb K (Potassium)

Résidus d'évap.

≤2.0 mg/L

Transmittance

210 nm, ≥60%
225 nm, ≥90%
245 nm, ≥98%

Indice de réfraction

n20/D 1.375 (lit.)

kinematic viscosity

0.50 cSt(20 °C)

Point d'ébullition

69 °C (lit.)

Pf

−95 °C (lit.)

Température de transition

flash point -22 °C

Densité

0.659 g/mL at 25 °C (lit.)

Température de stockage

2-30°C

Chaîne SMILES 

CCCCCC

InChI

1S/C6H14/c1-3-5-6-4-2/h3-6H2,1-2H3

Clé InChI

VLKZOEOYAKHREP-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

The product is a high purity solvent that ensures baseline stability, lowest impurity levels and high UV transmittance in LC-MS applications.

Application

Featured in screening and detection of estrogen-active nonylphenols in water by planar solid-phase extraction followed by high performance thin layer chromatography.
Also used in:
  • analysis of mineral oil saturated hydrocarbons in vegetable oils by LC-GC interface.
  • studies on sugars and organic acids in biological matrices using GC coupled to triple quadruple mass spectrometry (QqQ-MS).

Caractéristiques et avantages

  • no ghost peaks
  • full reproducibility
  • extends the lifetime of columns
  • optimized and tested for LC-MS applications
  • minimal background ion suppression
  • reduced risk of contamination
  • less exposure to hazardous chemicals

Notes préparatoires

Product filtered through a 0.2 μm filter

Remarque sur l'analyse

Purity (GC): ≥ 99.0 %
Identity (IR): conforms
Evaporation residue: ≤ 2.0 mg/l
Water: ≤ 0.005 %
Acidity: ≤ 0.0002 meq/g
Alkalinity: ≤ 0.0002 meq/g
Al (Aluminium): ≤ 10 ppb
Ca (Calcium): ≤ 10 ppb
Fe (Iron): ≤ 10 ppb
K (Potassium): ≤ 5 ppb
Mg (Magnesium): ≤ 10 ppb
Na (Sodium): ≤ 10 ppb
Transmission (at 210 nm): ≥ 60 %
Transmission (at 225 nm): ≥ 90 %
Transmission (from 245 nm): ≥ 98 %
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI positive): ≤ 2 ppb
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI negative): ≤ 20 ppb
Filtered by 0,2 µm filter.

Autres remarques

Explore various lab safety accessories and equipment for safe handling of solvents to increase your safety level from the first usage.

Informations légales

LICHROSOLV is a registered trademark of Merck KGaA, Darmstadt, Germany

Produit(s) apparenté(s)

Réf. du produit
Description
Tarif

Mention d'avertissement

Danger

Classification des risques

Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3

Organes cibles

Central nervous system, Nervous system

Code de la classe de stockage

3 - Flammable liquids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

-7.6 °F

Point d'éclair (°C)

-22 °C


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Quantification of sugars and organic acids in biological matrices using GC-QqQ-MS
Chemosphere, 207-223 (2018)
A lab-developed interface for liquid-gas chromatography coupling based on the use of a modified programmed-temperature-vaporizing injector
Zoccali M, et al.
Journal of Chromatography A, 1622, 461096-461096 (2020)

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique