Supelco

SP®-2560 GC-Kapillarsäule

L × I.D. 75 m × 0.18 mm, df 0.14 μm

Synonym(e):

GC column, biscyanopropyl siloxane

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
12352211
eCl@ss:
32119290
NACRES:
SB.54

Materialien

fused silica

Qualitätsniveau

Agentur

AOAC® 2012.13,Ce 1-h05,996.06
meets requirements for USP G5

Parameter

≤25-250 °C temperature (isothermal or programmed)

Beta-Wert

321

df

0.14 μm

Methode(n)

gas chromatography (GC): suitable (fast GC)

L × ID

75 m × 0.18 mm

Aktive Matrixgruppe

Non-bonded; poly(biscyanopropyl siloxane) phase

Anwendung(en)

agriculture
clinical
food and beverages

Säulenart

capillary highly polar

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Anwendung: Diese hoch polare Biscyanopropyl-Säule wurde speziell für die genaue Auftrennung von geometrischen (cis/trans-) Isomeren von Fettsäuremethylestern (FAME) entwickelt. Sie ist äußerst effektiv bei Anwendungen mit FAME-Isomeren.
USP-Code: Diese Säule entspricht den Anforderungen von USP G5.
Phase:
  • Nicht gebunden
  • Biscyanopropyl-Polysiloxan
Temperaturgrenzwerte:
  • Umgebungstemperatur bis 250 °C (isothermal oder programmiert)

Anwendung

SP®-2560 capillary GC column may be used for analysing fatty acid methyl esters (FAME) using capillary gas liquid chromatography (GLC).

Sonstige Hinweise

We offer a variety of chromatography accessories including analytical syringes

Rechtliche Hinweise

AOAC is a registered trademark of AOAC International
SP is a registered trademark of Sigma-Aldrich Co. LLC

Anwendung

Produkt-Nr.
Beschreibung
Preisangaben

Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

S Pegolo et al.
Journal of dairy science, 100(4), 2564-2576 (2017-02-13)
Buffalo milk is the world's second most widely produced milk, and increasing attention is being paid to its composition, particularly the fatty acid profile. The objectives of the present study were (1) to characterize the fatty acid composition of Mediterranean
M Cattani et al.
Journal of animal science and biotechnology, 8, 15-15 (2017-02-07)
In the last years, difficulties occurring in corn cultivation (i.e., groundwater shortages, mycotoxin contamination) have been forcing dairy farmers to consider alternative silages. Some experiments conducted on lactating cows have proven that the total replacement of corn silage with sorghum
Determination ofcis andtrans-Octadecenoic acids in margarines by gas liquid chromatography-infrared spectrophotometry.
Ratnayake, W. M. N., et al.
Journal of the American Oil Chemists' Society, 67, 804-810 (1990)
W M Ratnayake
Journal of AOAC International, 78(3), 783-802 (1995-05-01)
An infrared spectrophotometric (IR) method for the determination of total trans unsaturated fatty acid (trans) content and a combined gas-liquid chromatographic/infrared spectrophotometric (GC/IR) method for determination of fatty acid composition of partially hydrogenated vegetable oils (PHVO) were studied collaboratively in
Carla Ragonese et al.
Analytical chemistry, 81(13), 5561-5568 (2009-06-02)
The present research is focused on the evaluation of one 0.10 mm i.d. and two 0.25 mm i.d., ionic liquid (IL) stationary phase [1,9-di(3-vinyl-imidazolium) nonane bis(trifluoromethyl) sulfonyl imidate] columns, with lengths of 12 (the microbore capillary), 30 and 100 m

Chromatograms

application for SPE, suitable for GC

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.