18562
Zink Standard für ICP
TraceCERT®, 1 g/L Zn in nitric acid (nominal concentration)
Synonym(e):
Zinc ICP calibration standard
Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise
Alle Fotos(1)
About This Item
Empfohlene Produkte
Qualität
certified reference material
Qualitätsniveau
Produktlinie
TraceCERT®
Konzentration
1 g/L Zn in nitric acid (nominal concentration)
Methode(n)
ICP: suitable
Anwendung(en)
industrial qc
pharmaceutical
Format
single component solution
Allgemeine Beschreibung
This certified reference material (CRM) is produced in accordance with ISO 17034 and characterized in accordance with ISO/IEC 17025. This CRM is traceable to SI unit kg and measured against primary material from a National Metrology Institute (NMI), e.g. NIST.
Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.
Download your certificate at http://www.sigma-aldrich.com to view certified values, including uncertainty, date of expiry, and detailed information about trace impurities.
Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.
Download your certificate at http://www.sigma-aldrich.com to view certified values, including uncertainty, date of expiry, and detailed information about trace impurities.
Anwendung
Zinc ICP standard is a suitable calibration standard for elemental analysis by Inductively Coupled Plasma (ICP) technique.
Hinweis zur Analyse
1000 mg/L Zn in 2% Salpetersäure, hergestellt mit hochreinem Zn-Metall, HNO3 und Wasser
Sonstige Hinweise
For a complete product listing of our TraceCERT® range of CRMs for ICP and AAS, technical information, and example certificates please visit our ICP & AAS standards website
Rechtliche Hinweise
TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany
Signalwort
Warning
H-Sätze
Gefahreneinstufungen
Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2
Lagerklassenschlüssel
8B - Non-combustible corrosive hazardous materials
WGK
WGK 2
Flammpunkt (°F)
Not applicable
Flammpunkt (°C)
Not applicable
Persönliche Schutzausrüstung
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
Hier finden Sie alle aktuellen Versionen:
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Kunden haben sich ebenfalls angesehen
Nature biotechnology, 38(12), 1451-1459 (2020-07-08)
Lack of access to safe drinking water is a global problem, and methods to reliably and easily detect contaminants could be transformative. We report the development of a cell-free in vitro transcription system that uses RNA Output Sensors Activated by
Determination of phosphorus and metals in human brain proteins after isolation by gel electrophoresis by laser ablation inductively coupled plasma source mass spectrometry.
Journal of Analytical Atomic Spectrometry, 19.1, 149-152 (2004)
Biochimica et biophysica acta, 1862(4), 670-678 (2016-01-31)
Neovascularization and hemorrhaging are evident in advanced atherosclerotic plaques due to hypoxic conditions, and mediate the accumulation of metabolic substrates, inflammatory cells, lipids, and other blood born factors inside the plaque. Tissue factor (TF) pathway inhibitor (TFPI) is mainly expressed
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.