Direkt zum Inhalt
Merck

P3B050A05

Millipore

Pellicon® 3-Kassette mit Biomax® Membran

50kDa, A Screen, 0.57 m2

Synonym(e):

Pellicon® 3 Cassette with Biomax 50 kDa Membrane, A screen, 0.57 m2

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
23151806
eCl@ss:
32031623

Materialien

TPE seal
polyethersulfone
polypropylene screen
stainless steel cap (for end; polypropylene-encapsulated)

Qualitätsniveau

Leistungsmerkmale

holdup volume 69 mL (in feed channel)

Hersteller/Markenname

Pellicon®

Parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours)
4-6 L/min-m2 recirculation rate
40 psi max. transmembrane pressure at 4-50 °C
6.9 bar max. inlet pressure (100 psi)
80 psi max. transmembrane pressure at 4-40 °C

Methode(n)

analytical sample preparation: suitable
buffer exchange: suitable
protein purification: suitable (concentration)

Höhe

2.4 cm (0.93 in.)

Länge

20.6 cm (8.1 in.)

Breite

17.8 cm (7 in.)

Membranfläche

0.57 m2

Gravimetrisch bestimmte extrahierbare Substanzen

≤1500 mg/m2

Matrix

Biomax® (Membrane)

Porengröße

50 kDa NMWCO

pH-Wert

1-14

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Pellicon® 3 filtration devices are advanced, high-performance cassettes ideal for today’s higher titer therapeutic antibodies as well as the more demanding filtration processes that require higher operating pressures, temperatures and caustic cleaning regimes.

The Pellicon® 3 Cassette with Biomax® Membrane is perfect for the filtration of monoclonal antibodies and solutions containing albumin, hormones, vaccines and growth factors.

This P3B050A05 Pellicon® 3 ultrafiltration device features a pore size of 50 kDa NMWCO, a Biomax® 50 membrane, and dimensions measuring 2.4 cm (H) x 17.8 cm (W) x 20.6 cm (L).

Leistungsmerkmale und Vorteile

  • Rugged & reliable – ideally suited for today′s more demanding filtration processes
  • High performance – produces excellent resolution, yields and back-pressure resistance
  • Optimum product recovery – thanks to proven membrane technology
  • Void-free technology – leading-edge membranes resolve virtually any separation challenge
  • Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
  • Automated manufacturing – delivers unbeatable performance, consistency and reliability
  • Easy installation & care – simple to install and maintain

Sonstige Hinweise

These products are manufactured in a facility which adheres to Good Manufacturing Practices.

Hinweis zur Analyse

Gravimetric Extractables: after 24 hours in water at controlled room temperature

Rechtliche Hinweise

BIOMAX is a registered trademark of Merck KGaA, Darmstadt, Germany
Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Lagerklassenschlüssel

8B - Non-combustible corrosive hazardous materials

WGK

WGK 1


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.