Direkt zum Inhalt
Merck

W254430

Sigma-Aldrich

2-Heptanon

natural, 98%, FG

Synonym(e):

Methyl-pentylketon

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
CH3(CH2)4COCH3
CAS-Nummer:
Molekulargewicht:
114.19
FEMA-Nummer:
2544
Beilstein:
1699063
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12164502
PubChem Substanz-ID:
Flavis-Nummer:
7.002
NACRES:
NA.21

Qualität

FG
Fragrance grade
Halal
Kosher
natural

Qualitätsniveau

Agentur

follows IFRA guidelines
meets purity specifications of JECFA

Einhaltung gesetzlicher Vorschriften

EU Regulation 1223/2009
EU Regulation 1334/2008 & 178/2002
FDA 21 CFR 117

Dampfdichte

3.94 (vs air)

Dampfdruck

2.14 mmHg ( 20 °C)

Assay

98%

Form

liquid

Selbstzündungstemp.

739 °F

Expl.-Gr.

1.11 %, 65 °F
7.9 %, 121 °F

Brechungsindex

n20/D 1.408 (lit.)

bp

149-150 °C (lit.)

mp (Schmelzpunkt)

−35 °C (lit.)

Dichte

0.82 g/mL at 25 °C (lit.)

Anwendung(en)

flavors and fragrances

Dokumentation

see Safety & Documentation for available documents

Nahrungsmittelallergen

no known allergens

Allergener Duftstoff

no known allergens

Organoleptisch

creamy; waxy; cheesy; fruity

SMILES String

CCCCCC(C)=O

InChI

1S/C7H14O/c1-3-4-5-6-7(2)8/h3-6H2,1-2H3

InChIKey

CATSNJVOTSVZJV-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Verwandte Kategorien

Piktogramme

FlameExclamation mark

Signalwort

Warning

Gefahreneinstufungen

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Flam. Liq. 3 - STOT SE 3

Zielorgane

Central nervous system

Lagerklassenschlüssel

3 - Flammable liquids

WGK

WGK 1

Flammpunkt (°F)

105.8 °F - closed cup

Flammpunkt (°C)

41 °C - closed cup


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

M A Kotterman et al.
Gene therapy, 22(2), 116-126 (2014-12-17)
Gene delivery vectors based on adeno-associated viruses (AAV) have exhibited promise in both preclinical disease models and human clinical trials for numerous disease targets, including the retinal degenerative disorders Leber's congenital amaurosis and choroideremia. One general challenge for AAV is
Daniel Boloc et al.
PloS one, 10(8), e0135307-e0135307 (2015-08-13)
Retinitis pigmentosa (RP) is a highly heterogeneous genetic visual disorder with more than 70 known causative genes, some of them shared with other non-syndromic retinal dystrophies (e.g. Leber congenital amaurosis, LCA). The identification of RP genes has increased steadily during
Miriam Kolko et al.
Molecular vision, 20, 511-521 (2014-05-03)
To investigate the significance of calcium-independent phospholipase A₂, group VIA (iPLA2-VIA), in RPE cell survival following responses to sodium iodate (SI) in cell cultures. The human retinal pigment epithelium (RPE) cell line (ARPE-19) cells and primary mouse-RPE cultures were treated
S Böttcher et al.
Food chemistry, 169, 492-498 (2014-09-23)
The aim of the present study was to evaluate the off-flavour masking potential of pea dextrin (PD) in emulsions rich in ω-3 and ω-6-fatty acids in comparison with maltodextrin (MD) and 2-hydroxypropyl-β-cyclodextrin (HPBCD). After optimisation of the homogenisation procedure, stable
P N Valdmanis et al.
Oncogene, 34(1), 94-103 (2013-12-10)
Mice in which lung epithelial cells can be induced to express an oncogenic Kras(G12D) develop lung adenocarcinomas in a manner analogous to humans. A myriad of genetic changes accompany lung adenocarcinomas, many of which are poorly understood. To get a

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.