Skip to Content
Merck

Skip To

MPGL04GK2

Millipak® 40 Gamma Gold Capsule Media: Sterile Durapore® 0.22 µm

Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF) Inlet: 1/4 in. NPTM Outlet: 1/4 in. Stepped Hose Barb with Bell

Synonym(s):

Millipak® 40 Gamma Gold Filter, Millipak® Gold Filter

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice

About This Item

UNSPSC Code:
41104212
NACRES:
JA.14
eCl@ss:
33050190
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Millipak® 40 Gamma Gold Capsule Media: Sterile Durapore® 0.22 µm, Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF) Inlet: 1/4 in. NPTM Outlet: 1/4 in. Stepped Hose Barb with Bell

material

PVDF membrane

Quality Level

description

Sterile 0.22 μm membrane filter to remove particulates and bacteria at the point of dispense. For Milli-Q® Advantage A10/Academic/Biocel/Element/Synthesis/Plus/Gradient, Alpha-Q and Milli-DI® systems.

sterility

sterile

product line

EMPROVE® Filter

feature

hydrophilic

packaging

pkg of 2 units

manufacturer/tradename

Millipak®

parameter

0.35 bar max. differential pressure at 123 °C (Forward), 0.7 bar max. differential pressure at 25 °C (Reverse), 1.7 bar max. differential pressure at 80 °C (Forward), 4.1 bar max. differential pressure at 25 °C (Forward), 5.2 bar max. inlet pressure at 25 °C

inlet connection diam.

1/4 in.

outlet connection diam.

1/4 in.

impurities

<0.5  EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

gravimetric extractables

≤1.5 mg/device

matrix

Durapore®

pore size

0.22 μm pore size

fitting

male NPT inlet connection, outlet stepped hose barb (with bell)

compatibility

for use with Alpha-Q, for use with Milli-DI®, for use with Milli-Q® Academic, for use with Milli-Q® Advantage A10, for use with Milli-Q® Biocel, for use with Milli-Q® Direct, for use with Milli-Q® Element, for use with Milli-Q® Gradient, for use with Milli-Q® Plus, for use with Milli-Q® Reference, for use with Milli-Q® Synthesis

shipped in

ambient

General description

Millipak® membrane products are designed for routine filtration applications in the laboratory. Millipak® filters are best-in-class, proven products, used in lab water purification systems to remove particulates and bacteria to benefit the stringent requirements of scientific applications.

Application

Removes bacteria and particulates in ultrapure water, making it suitable for techniques used in the laboratory where bacterial control is crucial (cell culture, microbiology media preparation, etc.).

Features and Benefits

  • Millipak® membrane filters are made with Durapore® PVDF membranes to provide high flow rates and throughputs, low extractable and broad chemical compatibility.
  • Gamma-irradiated for additional bacteria control.
  • The membrane is supported by a rigid plastic disc with channels that ensures high water flow and resistance to pressure variations without the risk of membrane rupture.
  • Millipak® membrane filters use the unique, clean stacked disc design, allowing minimal hold-up volume and particle shedding.
  • Connects to the outlet of the water delivery point, such as the PODs of Milli-Q® water purification systems.The protective bell protects against intrusion of airborne bacteria contamination during dispensing.
  • The protective bell protects against intrusion of airborne bacteria contamination during dispensing.
  • Care-free maintenance: the filter is easily fitted and replaced.
  • Device configuration: Gamma Gold Capsule.
  • Sterile unit.
  • Delivered hermetically sealed, with its Certificate of Quality.

Preparation Note

This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: using sterilized device after a 200 mL flush and 24 hours in water at controlled room temperature

Other Notes

Directions for Use

  • Organism Retention: Microorganisms
  • Mode of Action: Filtering
  • Application: General laboratory analysis
  • Intended Use: Water purification
  • Instructions for Use: This item provides water filtered through 0.22 μm sterilizing-grade membranes. Refer to system equipment user guide section "Using the System" (available on USB key in the system box).
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
Emprove is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLI-DI is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPAK is a registered trademark of Merck KGaA, Darmstadt, Germany
Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
MPGP04001PRPK000A10PTIA04NN1
compatibility

for use with Alpha-Q, for use with Milli-Q® Academic, for use with Milli-Q® Biocel, for use with Milli-Q® Element, for use with Milli-Q® Plus, for use with Milli-Q® Synthesis, for use with Milli-DI®, for use with Milli-Q® Direct, for use with Milli-Q® Reference, for use with Milli-Q® Advantage A10, for use with Milli-Q® Gradient

compatibility

for use with Elix® Advantage, for use with Milli-Q® Advantage A10, for use with Milli-Q® Direct, for use with Milli-Q® Integral, for use with Milli-Q® Reference

compatibility

for use with Milli-Q® EQ 7008, for use with Milli-Q® EQ 7016, for use with Milli-Q® IX 7003, for use with Milli-Q® IX 7005, for use with Milli-Q® IX 7010, for use with Milli-Q® IX 7015, for use with Milli-Q® IQ 7003, for use with Milli-Q® IQ 7005, for use with Milli-Q® IQ 7010, for use with Milli-Q® IQ 7015

compatibility

for use with Milli-Q® CLX

sterility

sterile

sterility

non-sterile

sterility

-

sterility

sterile

pore size

0.22 μm pore size

pore size

0.22 μm pore size

pore size

0.5 μm pore size (High capacity filter CRW05 type)

pore size

0.22 μm pore size

manufacturer/tradename

Millipak®

manufacturer/tradename

Millipak®

manufacturer/tradename

-

manufacturer/tradename

Opticap®

packaging

pkg of 2 units

packaging

pkg of 1 unit

packaging

pkg of 1 unit

packaging

pkg of 1 unit

parameter

0.35 bar max. differential pressure at 123 °C (Forward), 1.7 bar max. differential pressure at 80 °C (Forward), 5.2 bar max. inlet pressure at 25 °C, 0.7 bar max. differential pressure at 25 °C (Reverse), 4.1 bar max. differential pressure at 25 °C (Forward)

parameter

-

parameter

≤6 bar pressure, 2 °C temp. range (40 °C), 5.0 L/min flow rate

parameter

-


Still not finding the right product?




Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library





Global Trade Item Number

SKUGTIN
MPGL04GK204053252465260

Questions

  1. Is there an alternative to MPGL04GK2? We change filters every 3 months.

    1 answer
    1. •The replacement part for a MPGL04GK2 is item number MPGL04001, which is the non-sterilized version of this filter.
      • Apart from this, there does not seem to be a direct replacement.
      • Note that MPGL04001 is autoclavable and can withstand up to 3 cycles of autoclaving for 90 minutes at 123°C.

      Helpful?

Reviews

No rating value

Active Filters