1.00658

Acetone

for gas chromatography MS SupraSolv®

Synonym(s):

Propanone

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice

About This Item

Linear Formula:
CH3COCH3
CAS Number:
Molecular Weight:
58.08
UNSPSC Code:
12352115
NACRES:
NA.03
EC Index Number:
200-662-2
MDL number:
Beilstein/REAXYS Number:
635680
Assay:
≥99.8% (GC)
Technique(s):
GC/MS: suitable
Bp:
56 °C/760 mmHg (lit.)
Vapor pressure:
184 mmHg ( 20 °C)
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Segment

vapor density

2 (vs air)

vapor pressure

184 mmHg ( 20 °C)

product line

SupraSolv®

assay

≥99.8% (GC)

form

liquid

autoignition temp.

465 °C (DIN 51794)

potency

5800 mg/kg LD50, oral (Rat), 20000 mg/kg LD50, skin (Rabbit)

expl. lim.

13.2 %

technique(s)

GC/MS: suitable

impurities

≤0.05% Water

evapn. residue

≤3.0 mg/L

color

APHA: ≤10

refractive index

n20/D 1.359 (lit.)

pH

5-6 (20 °C, 395 g/L in H2O)

capacity

1000  g/kg water absorbing capacity

bp

56 °C/760 mmHg (lit.)

mp

−94 °C (lit.)

transition temp

flash point <-20 °C

density

0.791 g/mL at 25 °C (lit.)

format

neat

storage temp.

2-30°C

SMILES string

CC(C)=O

InChI

1S/C3H6O/c1-3(2)4/h1-2H3

InChI key

CSCPPACGZOOCGX-UHFFFAOYSA-N

General description

SupraSolv® MS is a dedicated high-purity solvent grade specifically engineered for sample preparation and extraction in gas chromatography coupled with mass spectrometric detection (GC-MS)

Application

SupraSolv® MS solvents are routinely employed in highly demanding GC-MS-based analytical workflows, including polychlorinated biphenyl (PCB) determination in water and soil, pesticide residue analysis in food commodities such as fruits and vegetables, environmental contaminant profiling, dioxin screening, and multi-residue methods — applications in which unambiguous mass spectral identification and accurate trace-level quantification are of paramount regulatory and scientific importance.
Acetone′s luminesence intensity is dependent upon the solution components . The absorption of UV light by acetone, results in its photolysis and the production of radials .

Analysis Note

SupraSolv® MS solvents are produced via purification processes, yielding:
  • Extremely low levels of non-volatile residues and evaporation residues, preventing column contamination and ion source fouling
  • Minimal intrinsic volatile organic impurities, verified by GC-MS testing across the full chromatographic retention time window

Other Notes

Explore various lab safety accessories and equipment for safe handling of solvents to increase your safety level from the first usage.

Legal Information

SUPRASOLV is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
100020100012650501
description

for gas chromatography MS SupraSolv®

description

for liquid chromatography LiChrosolv®

description

for gas chromatography ECD and FID SupraSolv®

description

HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%

Quality Level

100

Quality Level

100

Quality Level

100

Quality Level

100

assay

≥99.8% (GC)

assay

≥99.8% (GC)

assay

≥99.8% (GC)

assay

≥99.9%

technique(s)

GC/MS: suitable

technique(s)

HPLC: suitable

technique(s)

gas chromatography (GC): suitable

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

form

liquid

form

liquid

form

liquid

form

liquid

density

0.791 g/mL at 25 °C (lit.)

density

0.791 g/mL at 25 °C (lit.)

density

0.791 g/mL at 25 °C (lit.)

density

0.791 g/mL at 25 °C (lit.)

mp

−94 °C (lit.)

mp

−94 °C (lit.)

mp

−94 °C (lit.)

mp

−94 °C (lit.)


Still not finding the right product?

Explore all of our products under Acetone


pictograms

FlameExclamation mark

signalword

Danger

Hazard Classifications

Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3

target_organs

Central nervous system

supp_hazards

Storage Class

3 - Flammable liquids

wgk

WGK 1

flash_point_f

1.4 °F - closed cup

flash_point_c

-17.0 °C - closed cup



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters