Solutions of this product are not sterile and contain a preservative, ProClin, to control contamination. In theory you could sterile filter P8920 through low protein binding filters, such as PVDF or PES. Sterile filtering will not remove the ProClin from P8920. Live cells should not be exposed to ProClin, as ProClin interrupts the Krebs cycle at 4 different sites. It would be best to purchase the powder as P1524 and then sterile filter after the solution has been prepared.
P8920
Poly-L-lysine solution
0.1 % (w/v) in H2O
Synonym(s):
2-(4-Cyanoanilino)-4,6-dichloropyrimidine, 4-[(4,6-Dichloro-2-pyrimidinyl)amino]benzonitrile
About This Item
Recommended Products
biological source
synthetic
shelf life
Expiry date on the label.
mol wt
150,000-300,000
concentration
0.1 % (w/v) in H2O
color
colorless
application(s)
hematology
histology
storage temp.
room temp
SMILES string
N([C@@H](CCCCN)C(=O)N[C@@H](CCCCN)C(=O)O)C(=O)[C@@H](N)CCCCN
InChI
1S/C18H38N6O4/c19-10-4-1-7-13(22)16(25)23-14(8-2-5-11-20)17(26)24-15(18(27)28)9-3-6-12-21/h13-15H,1-12,19-22H2,(H,23,25)(H,24,26)(H,27,28)/t13-,14-,15-/m0/s1
InChI key
WBSCNDJQPKSPII-KKUMJFAQSA-N
Looking for similar products? Visit Product Comparison Guide
Application
Biochem/physiol Actions
Components
Preparation Note
replaced by
Signal Word
Warning
Hazard Statements
Precautionary Statements
Hazard Classifications
Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1
Storage Class Code
12 - Non Combustible Liquids
WGK
WGK 3
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Choose from one of the most recent versions:
Certificates of Analysis (COA)
Don't see the Right Version?
If you require a particular version, you can look up a specific certificate by the Lot or Batch number.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Articles
Human Protein Atlas uses A-431, U-251 MG, and U-205 cell lines with Prestige Antibodies for organelle mapping.
Human Protein Atlas uses A-431, U-251 MG, and U-205 cell lines with Prestige Antibodies for organelle mapping.
Human Protein Atlas uses A-431, U-251 MG, and U-205 cell lines with Prestige Antibodies for organelle mapping.
Human Protein Atlas uses A-431, U-251 MG, and U-205 cell lines with Prestige Antibodies for organelle mapping.
Related Content
Learn about the clinical study of blood, blood-forming organs, and blood diseases including the treatment, prevention, and stains and dyes used in hematology testing.
Learn about the clinical study of blood, blood-forming organs, and blood diseases including the treatment, prevention, and stains and dyes used in hematology testing.
Learn about the clinical study of blood, blood-forming organs, and blood diseases including the treatment, prevention, and stains and dyes used in hematology testing.
Learn about the clinical study of blood, blood-forming organs, and blood diseases including the treatment, prevention, and stains and dyes used in hematology testing.
-
Bonjour, Est ce que cette PLL est stérile ? Est-il possible de la filtrer ? Je vous remercie. Cordialement. Mme Boroni
1 answer-
Helpful?
-
-
Hello! How many microscopy slides can I adhesive for every 100 milliliters of this solution( Poli-L- Lisine),? Gratitude!
1 answer-
The number of slides that may be coated is dependent upon the surface area. The general use instructions recommend using 0.5 - 1.0 mL per 25 cm2 coating area - the 25 cm2 value is based on a T-25 tissue culture flask. A standard microscope slide has an approximate area of 1.3 cm2.
Please see the link below to review the product datasheet which included a general protocol for coating: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/784/704/p6407pis.pdf
Helpful?
-
-
Is Product P8920, Poly-L-lysine solution, recommended for cell culture use?
1 answer-
No, the product contain 0.01% thimerosal as a preservative. For cell culture use, product P4832 is recommended. This solution has the same molecular weight as P8920 but contains no preservative. P4832 is sterile filtered and is considered suitable for cell culture use.
Helpful?
-
-
What is the Department of Transportation shipping information for this product?
1 answer-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
Helpful?
-
-
What are the recommended uses for Product P8920, Poly-L-lysine solution?
1 answer-
P8920 was developed for use in coating slides intended for use in either histology or immunohistochemistry. Poly-L-lysine is preferred for uses such as silver staining procedures that require an alkaline pH. Silane coated slides may be more effective is a low pH is required.
Helpful?
-
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service