21004
Cesium iodide
analytical standard, suitable for mass spectrometry (MS)
Sign Into View Organizational & Contract Pricing
All Photos(2)
About This Item
Recommended Products
Quality Level
grade
analytical standard
Assay
99.999%
technique(s)
mass spectrometry (MS): suitable
mp
626 °C (lit.)
density
4.51 g/mL at 25 °C (lit.)
application(s)
cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care
format
neat
SMILES string
[I-].[Cs+]
InChI
1S/Cs.HI/h;1H/q+1;/p-1
InChI key
XQPRBTXUXXVTKB-UHFFFAOYSA-M
Looking for similar products? Visit Product Comparison Guide
Related Categories
General description
Cesium iodide is a simple ionic salt. It has the capacity to undergo second order transformation from cubic B2 structure to body-centered tetragonal structure at low pressures. It is mostly used as input screens of X-ray image intensifiers.
Application
Cesium iodide has been used as calibration standard during native electrospray ionization time-of-flight mass spectrometry (ESI-TOF MS) analysis for measuring protein samples, from protein aggregates.
Suitable as standard for electrospray ionisation MS (ESI)
Features and Benefits
Frequently used in devices such as phosphor screens for medical imaging, scintillators, calorimeters and a variety of particle detectors.
Signal Word
Warning
Hazard Statements
Precautionary Statements
Hazard Classifications
Aquatic Acute 1 - Repr. 2
Storage Class Code
13 - Non Combustible Solids
WGK
WGK 2
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Personal Protective Equipment
dust mask type N95 (US), Eyeshields, Gloves
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Org. Mass Spectrom., 27, 660-660 (1992)
Medical physics, 31(9), 2594-2605 (2004-10-19)
Columnar structured cesium iodide (CsI) scintillators doped with Thallium (Tl) have been used extensively for indirect x-ray imaging detectors. The purpose of this paper is to develop a methodology for systematic investigation of the inherent imaging performance of CsI as
Rapid communications in mass spectrometry : RCM, 5(10), 484-490 (1991-10-01)
The direct coupling of capillary electrophoresis (CE) and mass spectrometry, combined with ionspray ionization using a coaxial capillary arrangement, is described. The CE/mass spectrometer interface is shown to be effective for the analysis of native and tryptic peptides and of
Pharmaceutical research, 27(10), 2197-2204 (2010-08-04)
The aim of this study was to develop a method to characterize intact soluble monoclonal IgG1 antibody (IgG) oligomers by mass spectrometry. IgG aggregates (dimers, trimers, tetramers and high-molecular-weight oligomers) were created by subjecting an IgG formulation to several pH
Science (New York, N.Y.), 223(4631), 53-56 (1984-01-06)
Cesium iodide, a simple ionic salt at low pressures, undergoes a second-order transformation at 40 gigapascals (400 kilobars) from the cubic B2 (cesium chloride-type) structure to the body-centered tetragonal structure. Also, the energy gap between valence and conduction bands decreases
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service