์ฝ˜ํ…์ธ ๋กœ ๊ฑด๋„ˆ๋›ฐ๊ธฐ
Merck
  • Rapid non-genomic and concentration-dependent effects of progesterone in c4-I cells on the proposed tumor-marker - ratio between extracellular cgmp and cAMP levels.

Rapid non-genomic and concentration-dependent effects of progesterone in c4-I cells on the proposed tumor-marker - ratio between extracellular cgmp and cAMP levels.

International journal of oncology (1995-06-01)
A Orbo, K Kjorstad, R Jaeger, G Sager
์ดˆ๋ก

The extracellular cGMP levels or the ratio between extracellular levels of cGMP and cAMP (cGMP(ex)/cAMP(ex)) have been proposed as tumor marker for premalignant and malignant diseases of the uterine cervix. More than 50% of cervical cancers occur in premenopausal women and detailed information about hormonal and drug effects on the extracellular levels of cyclic nucleotides is of importance. In the present study we have investigated the effect of progesterone (0.1-100 mu M), theophylline (1-1000 mu M), probenecid (0.1-100 mu M) and verapamil (0.1-100 mu M) on cGMP(ex)/cAMP(ex) of C4-I cells (a human cell line derived from a squamous carcinoma of the uterine cervix). Within 30 min progesterone caused a concentration-dependent elevation of cGMP(ex)/cAMP(ex), whereas the other compounds had no marked effect. Identical results were obtained for C4-I cells in monolayer and in suspension. The effects were explained by the observation that progesterone stimulated cGMP efflux, but inhibited the cAMP efflux. The other compounds inhibited the export of both nucleotides to a similar degree. The present data suggest that progesterone affects the export of cyclic nucleotides in non-genomic manner and may hamper the interpretation of cGMP(ex)/cAMP(ex) in the luteal phase in premenopausal women with cancer of the uterine cervix.

MATERIALS
์ œํ’ˆ ๋ฒˆํ˜ธ
๋ธŒ๋žœ๋“œ
์ œํ’ˆ ์„ค๋ช…

Supelco
ORBOโ„ข 609 Amberliteโ„ข XADยฎ-2 (20/50) 400/200 mg, W,W,W separators, O.D. ร— L 8 mm ร— 110 mm, pkg of 50 ea
Supelco
ORBOโ„ข 402 Tenaxยฎ TA specially treated (35/60), 100/50 mg, W,W,W separators, O.D. ร— L 8 mm ร— 100 mm, pkg of 50 ea
Supelco
ORBOโ„ข 23 2-HMP on Amberliteโ„ข XADยฎ-2 (20/40), 120/60 mg, W,W,W separators, O.D. ร— L 6 mm ร— 85 mm, pkg of 25 ea
Supelco
ORBOโ„ข 49P (OVS) Supelpakโ„ข-20 specially treated Amberliteโ„ข XADยฎ-2 (20/40), 270/140 mg, RC,GFF,F,F (specially cleaned) separators, O.D. ร— L 13-8 mm ร— 75 mm , OSHA Versatile Sampler (OVS) Tube, pkg of 10 ea
Supelco
ORBOโ„ข 502 Activated Silica Gel (20/45) 100/50 mg, W,W,F separators, O.D. ร— L 6 mm ร— 75 mm, pkg of 50 ea
Supelco
ORBOโ„ข 53 Activated Silica Gel (20/40) specially cleaned, 400/200 mg with Glass Fiber Filters, GFF,F,F separators, O.D. ร— L 7 mm ร— 100 mm, pkg of 50 ea
Supelco
ORBOโ„ข 554 H2SO4 on Silica Gel (20/40) 150/75 mg, W,W,W separators, O.D. ร— L 6 mm ร— 75 mm, pkg of 50 ea
Supelco
ORBOโ„ข 80 Coated Filter, with cassettes unassembled
Supelco
ORBOโ„ข 90 Carboxenยฎ 564 (20/45), 160/80 mg, W,F,F separators, O.D. ร— L 6 mm ร— 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
ORBOโ„ข 65P (OVS) Amberliteโ„ข XADยฎ-4 specially cleaned, 160/80 mg, RC,GFF,F,F (specially cleaned) separators, O.D. ร— L 13-8 mm ร— 75 mm , OSHA Versatile Sampler (OVS), pkg of 10 ea
Supelco
ORBOโ„ข 92 Carboxenยฎ 564 (20/45), 160/80 mg, W,F,F separators, O.D. ร— L 6 mm ร— 75 mm, pkg of 25 ea, for analyte group Vinyl acetate
Supelco
ORBOโ„ข 43 Supelpakโ„ข-20 specially treated Amberliteโ„ข XADยฎ-2 (20/40), 100/50 mg, W,W,W (specially treated) separators, O.D. ร— L 8 mm ร— 100 mm, pkg of 50 ea
Supelco
ORBOโ„ข 24 2-HMP on Amberliteโ„ข XADยฎ-2 (20/40), 150/75 mg, W,W,W separators, O.D. ร— L 6 mm ร— 105 mm, pkg of 25 ea
Supelco
ORBOโ„ข 52 Small Activated Silica Gel (20/40) 150/75 mg, pk 50, W,W,F separators, O.D. ร— L 6 mm ร— 75 mm, pkg of 50 ea
Supelco
ORBOโ„ข 80 Isocyanate Filter, with cassettes: no, filter O.D. 37 mm, pkg of 25 ea