Grade
reagent grade
제품 라인
Vetec™
분석
99%
형태
crystalline powder
pH
3.0-5.0 (103.6 g/L)
유용한 pH 범위
8.6-10.0
pKa(25 °C)
9.3
solubility
water: 0.176 g/mL, clear, colorless
SMILES string
OS(=O)(=O)CCNC1CCCCC1
InChI
1S/C8H17NO3S/c10-13(11,12)7-6-9-8-4-2-1-3-5-8/h8-9H,1-7H2,(H,10,11,12)
InChI key
MKWKNSIESPFAQN-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
법적 정보
Vetec is a trademark of Merck KGaA, Darmstadt, Germany
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
Dalton transactions (Cambridge, England : 2003), 48(23), 8238-8247 (2019-05-17)
The solution- and solid-state interactions between the octadentate siderophore mimic 3,4,3-LI(1,2-HOPO) (343HOPO) and group IV metal ions were investigated using high-resolution mass spectrometry, liquid chromatography, UV-visible spectrophotometry, metal-competition batch titrations, and single crystal X-ray diffraction. 343HOPO forms a neutral 1 : 1
The Analyst, 145(17), 5897-5904 (2020-07-17)
This work provides the pKa at the biorelevant temperature of 37 °C for a set of compounds proposed as internal standards for the internal standard capillary electrophoresis (IS-CE) method. This is a high throughput method that allows the determination of
Journal of chromatography. A, 1229, 268-273 (2012-02-11)
Several glycosphingolipids were labeled with the fluorphore Bodipy-Fl and analyzed using capillary electrophoresis with laser-induced fluorescence detection. GM1-, LacCer-, and Cer-Bodipy-Fl were prepared through acylation using the N-hydroxysuccinimide ester of Bodipy-Fl. Several other glycosphingolipids including GT1a-, GD1a-, GM2-, GM3-, GD3-
Electrophoresis, 19(12), 2257-2261 (1998-10-07)
The suitability of relatively slow (low absolute value of mobility) coanionic buffers in background electrolytes (BGEs) for indirect photometric detection of anions by capillary electrophoresis was investigated. As a model system, 2-(cyclohexylamino)ethanesulfonic acid (CHES) was used to buffer the indirect
Electrophoresis, 24(17), 2887-2895 (2003-09-16)
A systematic evaluation of continuous flow-counterbalanced capillary electrophoresis for microscale preparative applications is presented. The success of the technique was found to depend on the specific nature of the analyte and background electrolyte and was most heavily influenced by factors
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.