콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

54241-U

Supelco

Supel-Select SCX SPE Tube

bed wt. 60 mg, volume 3 mL, pk of 50

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41115712
NACRES:
NB.21

material

PE frit (20 μm)
polypropylene hardware

품질

MS Friendly

구성

bed wt., 60 mg

포장

pk of 50

기술

solid phase extraction (SPE): suitable

표면적

160-420 m2/g

용적

3 mL

기질

Sulfonic acid functionalized hydrophilic modified styrene polymer particle platform

기질 활성군

sulfonic acid phase

입자 크기

50-70 μm

공극 크기

80-200 Å pore size

응용 분야

food and beverages

분리 기술

ion exchange

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Retention Mechanism: Ion-Exchange
Sample Matrix Compatibility: Aqueous solutions (biological fluids, water)

  • Sulfonic acid functionalized hydrophilic modified styrene polymer
  • Developed for the extraction of a highly broad range of compounds from aqueous samples
  • Retention predominately based on ion-exchange; however, because the phase is hydrophilic modified, it is amenable to polar compounds as well.

View related article: Isolation and LC-MS Characterization of Illicit Bath Salts in Urine

특징 및 장점

  • Excellent sample prep performance at a lower price
  • Amenable to generic methodology - save time, money, and headache during method development
  • Greater capacity allows for smaller bed weights = smaller elution volumes = time savings in sample processing
  • Resistance to overdrying allows for more robust methdology
  • Low UV and MS extractables for lower background and greater sensitivity
  • Stringent production and QC guidelines offer greater lot-to-lot, tube-to-tube, and well-to-well consistency for improved accuracy and precision

법적 정보

Supel is a trademark of Sigma-Aldrich Co. LLC

픽토그램

Exclamation mark

신호어

Warning

유해 및 위험 성명서

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

표적 기관

Respiratory system

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


Choose from one of the most recent versions:

시험 성적서(COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

프로토콜

Optimize β-glucuronidase hydrolysis for glucuronide metabolite analysis considering factors like time, temperature, pH, and enzyme concentration.

Normal-phase SPE separates analytes based on polar interaction with sorbents in diverse sample matrices.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.