추천 제품
Grade
analytical standard
포장
ampule of 1000 mg
기술
HPLC: suitable
gas chromatography (GC): suitable
응용 분야
environmental
형식
neat
저장 온도
2-8°C
InChI
1S/C15H10N2O2/c18-10-16-14-5-1-12(2-6-14)9-13-3-7-15(8-4-13)17-11-19/h1-8H,9H2
InChI key
UPMLOUAZCHDJJD-UHFFFAOYSA-N
애플리케이션
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Inhalation - Carc. 2 - Eye Irrit. 2 - Resp. Sens. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT RE 2 Inhalation - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
11 - Combustible Solids
WGK
WGK 1
Flash Point (°F)
411.8 °F - closed cup
Flash Point (°C)
211 °C - closed cup
개인 보호 장비
dust mask type N95 (US), Eyeshields, Faceshields, Gloves
Dominika Swierczyńska-Machura et al.
Medycyna pracy, 62(6), 567-577 (2012-02-09)
The aim of the study was to analyze the data obtained during the diagnostic process and their real values in the final diagnosis of patients exposed to diisocyanates amd suspected of occupational allergic disease of the respiratory system The patients
H D Hoffmann et al.
Toxicology letters, 199(3), 364-371 (2010-10-12)
Polyurethanes (PU) are polymers made with diisocyanates such as MDI (4,4'-methylene diphenyl diisocyanate) and TDI (2,4-toluene diisocyanate and 2,6-toluene diisocyanate). Investigations have been undertaken with MDI and TDI to assess dermal uptake and resulting systemic exposure. Absorption, distribution and excretion
Hanna K Lindberg et al.
Mutation research, 723(1), 1-10 (2011-04-02)
Toluene diisocyanate (TDI) and 4,4'-methylenediphenyl diisocyanate (MDI), used in the production of polyurethane foam, are well known for their irritating and sensitizing properties. Contradictory results have been obtained on their genotoxicity. We investigated the genotoxicity and protein binding of inhaled
Unique foreign body ingestions in the pediatric population.
Sheila Isabelle Goertemoeller et al.
Journal of emergency nursing: JEN : official publication of the Emergency Department Nurses Association, 36(2), 178-179 (2010-03-10)
Malin Engfeldt et al.
Contact dermatitis, 68(3), 175-180 (2012-10-11)
A 43-year-old woman was referred by her occupational health service with suspected occupational contact dermatitis. In connection with the investigation, a workplace visit was undertaken at her company, which used an adhesive based on pre-polymeric diphenylmethane diisocyanate in one of
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.