추천 제품
Grade
analytical standard
포장
ampule of 1 mL
농도
1000 μg/mL in methanol
기술
HPLC: suitable
gas chromatography (GC): suitable
응용 분야
environmental
형식
single component solution
저장 온도
2-8°C
SMILES string
CCCl
InChI
1S/C2H5Cl/c1-2-3/h2H2,1H3
InChI key
HRYZWHHZPQKTII-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Chloroethane is clear and colourless gas with a pungent type of odor, which can be commonly used in topical vapocoolant sprays.
애플리케이션
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
기타 정보
This product is now available as a certified reference solution. Please reference CRM40015
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
표적 기관
Eyes,Central nervous system
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point (°F)
51.8 °F - closed cup
Flash Point (°C)
11 °C - closed cup
Vapocoolant Spray Effectiveness on Arterial Puncture Pain: A Randomized Controlled Clinical Trial
Acta Medica Iranica, 55, 87-91 (2017)
The journal of physical chemistry. A, 114(15), 5092-5098 (2010-03-27)
The photocatalytic degradation of chlorinated ethanes was studied in a tubular photoreactor packed with TiO(2) pellets prepared by sol-gel method. The steady-state condition was not obtained, but the deterioration in the photocatalytic activity was observed during the irradiation. Effects of
Pediatric emergency care, 25(6), 415-419 (2009-06-17)
Conscious sedation is used frequently to perform procedures that may be undertaken with or without minimal sedation. Fracture manipulation can be performed with minimal discomfort in the awake patient using various techniques-for example, intravenous regional anesthesia, nerve blocks, and hematoma
The Journal of organic chemistry, 75(12), 4212-4217 (2010-05-21)
The enhanced reactivity exhibited by six pseudo-alpha-bases, RC[triple bond]CZ(-) (R = H and Cl; Z = O, S, and Se) in gas-phase E2 reactions with ethyl chloride was examined at the G2(+) level. It is found that anomalous reactivity is
The Clinical journal of pain, 25(6), 490-494 (2009-06-23)
The purpose of this study was to evaluate the effectiveness of vapocoolant for preschoolers' immunization injection pain relief. Fifty-seven 4 to 6-year-old children were randomized into vapocoolant alone or typical care conditions. Pain was measured at the baseline and at
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.